EasyManua.ls Logo

Scania DC09 - Renewing the Particulate Filter

Scania DC09
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Other
OPM 100 en-GB 102
© Scania CV AB 2023, Sweden
Renewing the particulate fil-
ter
WARNING!
P3 type respiratory protective equipment/filter
mask, eye protection and gloves should be worn
for any work where there is a risk of exposure to
dust from the particulate filter. A face mask,
gloves and eye protection must be worn when
cleaning the filter unit. Use protective equipment
from the time the filter unit is exposed until the
time cleaning is complete. Safety clearance for
unprotected people is 3 m.
Do not eat, drink or smoke while work is in pro-
gress.
Any dust from the particulate filter should be re-
moved using a vacuum cleaner with a HEPA fil-
ter that can filter out particles down to a particle
size of 0.3 microns, in order to minimise expo-
sure.
Wash your hands thoroughly after work on the
particle filter.
IMPORTANT!
Be careful when handling the sensor body. It is
sensitive and must not be bent or straightened.
Renew the sensor if it is bent.
Tool
Number Designation Illustration Tool board
99 405 Clutch bleeder D6
99 654 VCI3 N/A
2 290 856 17 mm, Special socket, slot-
ted, 1/2"
N/A

Table of Contents