Power classes
OPM 100 en-GB 16
© Scania CV AB 2023, Sweden
Power classes
Scania supplies engines in 4 different power classes:
ICFN, Continuous service: Intended for continuous use and an unlimited number of operational hours per
year at a total load factor of 100%.
IFN, Intermittent service: Intended for periodic use, where the rated power is available for 1 hour per 6-
hour period. The total load factor must not exceed 80% of the rated power. Unlimited number of operational
hours per year.
PRP, Prime Power: Intended for continuous use and an unlimited number of operational hours with vary-
ing loads. For continuous operation and unlimited annual operating time with varying loads. Max. average
load factor of 70% of rated power during 24 hours of operation. 1 hour/12 hour period over 100% load. Max.
25 hours accumulated service time over 100% load per year. This power class applies to single-speed en-
gines.
COP, Continuous power: Intended for continual use with a non-varying load and an unlimited number of
operational hours.
The engine serial numbers and power classes for the engines that are used in this installation should be listed
below: You can find the power class of your engine in the engine type data sheet on the Scania website,
www.scania.com.
Engine serial num-
ber:
Motor type:
Engine power: kW at rpm
ICFN, Continuous service
IFN, Intermittent service
PRP, Prime power
COP, Continuous Power