OPM 100 en-GB 30
© Scania CV AB 2023, Sweden
Starting and driving
Reductant pump
There are two types of reductant pumps:
Reductant pump with mechanical overflow
protection, left-hand one in the illustration
Reductant pump with electronic overflow
protection, right-hand one in the illustration
IMPORTANT!
Function tests are carried out on new reductant
pumps. This may cause crystallised urea to be
present inside the reductant pump.
Before fitting of a new reductant pump with me-
chanical overflow protection (the left-hand one
in the illustration), the pump should be blown
clean with compressed air (approx. 6 bar)
through the suction union for at least 3 seconds.
The reductant pump (to the right in the illustra-
tion) with electronic overflow protection must
never be blown clean with compressed air.
checks before driving
Carry out daily maintenance as described in the
maintenance schedule prior to operation. See
Maintenance interval
.