Intake system
Cooling system
Fuel system
Electrical system
Permissible pressure drop in the intake system with cleaned or new filter
(mbar/psi)
30/0.44
Permissible pressure drop in the intake system with blocked (dirty) filter
(mbar/psi)
65/0.94
Coolant volume, excluding radiator (dm
3
/US gallons)
DC09 084/085/086/089/384/385/386/387/389A 16/4.2
Other engine types 15/4.0
Coolant volume including 1.1 m
2
radiator (dm
3
/US gallons)
DC09 084/085/086/089/384/385/386/387/389A 38/10.0
Other engine types 37/9.8
Coolant temperature (°C/°F) 90-95/194-203
Number of thermostats 1
Thermostat opening temperature (°C/°F) 80/176 and 87/189
Injection system XPI (Extra High Pressure In-
jection)
Engine management system EMS
Fuel filter Paper filter from Scania
Water separating prefilter Paper filter from Scania
Filter for tank venting Paper filter from Scania
Type 1-pin, 24 V, DC
Starter motor, standard equipment 1-pin, 24 V, 6 kW
Alternator, standard equipment 1-pin, 28 V, 100 A