OPM 250 en-GB 27
©
Scania CV AB 2016, Sweden
Inspection
Engines with few hours of op-
eration
IMPORTANT!
On engines with few hours of operation, inspec-
tion must be carried out annually or every 5
years.
Stand-by generator sets and the like that are not
used regularly should be test run and checked in
accordance with the manufacturer's instructions.
The following inspection points must be carried
out once the engine has been warmed up to oper-
ating temperature.
1. Checking oil level.
2. Checking coolant level.
3. Checking vacuum indicator.
4. Checking fuel level.
5. Check for engine leaks.