OPM 250 en-GB 36
©
Scania CV AB 2016, Sweden
Lubrication system
7.
Remove the paper insert and scrape away
any remaining dirt deposits inside the rotor
cover. If the deposits are thicker than 28 mm,
the centrifugal oil cleaner must be cleaned
more often.
8. Wash the parts.
9. Inspect the 2 nozzles on the rotor. Ensure that
they are not blocked or damaged. Renew any
damaged nozzles.
10. Check that the bearings are undamaged.
333 044
333 037