Assembly and settings
Item Mounting JGP-P
40 50 64 80 100
1 Thread in the main air
connections
M3 M5 M5 M5 G1/8
Max. depth of engagement
from locating surface [mm]
4 5 6 6 7
2 Thread in the air purge
connection
M3 M3 M5 M5 M5
Max. depth of engagement
from locating surface [mm]
3.9 5 6 6 6
Item Mounting JGP-P
125 160 200 240 300
1 Thread in the main air
connections
G1/8 G1/8 G1/8 G1/8 G1/4
Max. depth of engagement
from locating surface [mm]
7 7 7 7 12
2 Thread in the air purge
connection
M5 M5 M5 M5 M5
Max. depth of engagement
from locating surface [mm]
6 6 6 6 6
Air purge connection The air purge is used in order to make it more difficult for dirt and
dust to penetrate into the product and the guiding areas.
2702.00 | JGP-P | Assembly and Operating Manual | en | 1469637