Assembly and settings
32 02.00 | JGP-P | Assembly and Operating Manual | en | 1469637
5.4.3 Switch-off hysteresis for magnetic switches
Sensors MMS 22, MMS-P 22, MMS 22-PI1 and MMS 22-PI2
The smallest detectable difference in stroke is defined in the
following table:
The smallest detectable difference in stroke based on the nominal stroke
For grippers with X mm
nominal stroke per jaw
Min. query range per jaw/
min. queried stroke difference per jaw
X ≤ 5 mm 30% of the nominal stroke per jaw
X > 5 mm to X ≤ 10 mm 20% of the nominal stroke per jaw
X > 10 mm 10% of the nominal stroke per jaw
Example: Product with 7 mm nominal stroke per jaw
7 mm * 20% = 1.4 mm
5.4.4 Setting dimensions for position sensors
The setting dimension applies to the following sensors: FPS, APS-
M1, APS-Z80
Setting dimension l3 of the base jaw (2) up to the front of the control cam (1)
Size Setting dimension l3 [mm]
FPS APS-M1 APS-Z80
64-1 -0.8 0 +0.7
64-2 -1.1 0 -3.8
80-1 -2 0 0
80-2 -2.6 0 -3.3
100-1 -2.7 0 -1
100-2 -3 0 -3.8
125-1 -3.8 0 +1.7
125-2 -7.8 0 -2.3
160-1 0 0 0
160-2 -4.2 0 -7.1
200-1 +2.2 0 0
200-2 -7.5 0 -3.6
240-1 +4 0 +3
240-2 -8.2 0 -4.6
300-1 - 0 0