50 02.00 | JGP-P | Assembly and Operating Manual | en | 1469637
7.3 Lubricants/Lubrication points (basic lubrication)
WARNING
Risk of injury due to contact with lubricants!
Lubricant may cause irritation and allergic reactions if it contacts
the skin or eyes.
Avoid contact between lubricant and skin or eyes.
Wear safety goggles and protective gloves.
Observe information on the safety data sheet of the lubricant.
SCHUNK recommends the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly
apply lubricant with a lint-free cloth.
Lubricant point Lubricant
Metallic sliding surfaces JGP-P 40: microGLEIT GSV 790
JGP-P 50-300: Toothgood 1
All seals Sealgood 1
Cylinder surfaces Sealgood 1
7.4 Lubricate product
WARNING
Risk of injury due to moving parts!
When moving the gripper fingers, body parts may get squashed/
hit causing severe injuries.
Do not interfere with moving parts during operation.
Observe position and direction of movement of the gripper
fingers.