Assembly and settings
5.4.8 Mounting programmable MMS 22-P 22 magnetic switch
CAUTION
Risk of damage to the sensor during assembly!
Observe the maximal tightening torque.
NOTE
If there is no T-nut available, slide the sensor according to
dimension I1 into the groove (2), }5.4.2 [
/
31].
1. Turn the sensor (1) into the groove (2).
OR: Slide the sensor (1) into the groove (2) until the sensor (1)
stops at the T-nut (3).
2. Secure the sensor (1) using the set-screw (4).
Tightening torque: 10Ncm
3. Adjust sensor (1), see sensor assembly and operating manual.
3702.00 | JGP-P | Assembly and Operating Manual | en | 1469637