Maintenance and Care
10.00 | SWS 005 – 300 | Assembly and Operating Manual | en | 389456
47
Sensors and Cables Inspect sensor cables and connectors for any damage, cuts, and
abrasion.
Electrical Contacts/
Pin Block (Modules)
Inspect for wear and abrasion.
Exposed contacts may be subject to damage during normal operation.
Clear debris from the area of the contacts using compressed air.
Do not directly clean contacts as abrasion may occur and the
performance of the contact may be compromised.
8.2 Lubrication
8.2.1 External
The quick-change is factory-lubricated. For many applications this
lubrication is sufficient for the life of the product.
In some high-cycle applications or applications subject to
moisture, the Tool Changer locking mechanism wear and oxidation
can be reduced by applying a thin film of anti-seize compound
(molybdenum disulfide grease) to the locking balls, cam, and
bearing race at periodic intervals (e.g., every 250,000 cycles).
8.2.2 Internal
The internal piston and O-ring do not need lubrication unless the
unit is disassembled. In this case, a Teflon-based lubricant such as
Magnalube® is recommended.
8.3 Cleaning and Lubrication of the Locking Mechanism
8.3.1 Cleaning and Lubrication of the Locking Mechanism and
Alignment Pins
Cleaning balls and outer
surfaces of male coupling
Cleaning balls, cam an inner
surfaces of male coupling
Ø The locking mechanism must be in the unlock state before
cleaning.