INCU-SHAKE Compact Stackable shaking Incubator Manual V2023.1
22
6.3.1 CTRL MODE-- Switch of Control Mode - Temperature & Speed
The incubator can be set to run with fixed functional parameters settings, or with
program up to 10 different segments, each with their own Ramp Time, Ramp End
Temperature, Hold Time and Speed.
To select between Fixed Value mode and Programmable mode, follow the below
steps,
Press "Stop" button in the home page to stop the current operation.
Enter "FUNC" page.
Press the "CTRL MODE" to switch the mode between "FIXED" and "PROG".
6.3.2 KEEP-- Switch of Keep Function-Temperature Holding Function
This function will enable or disable the system to keep constant temperature
controlling at the temperature setpoint while the system is not in operation, or once
the timer runs out.
With this function enabled, the unit can be used for static incubation while it’s in
standby mode.
Under Programmable mode, the temperature will remain under control at the ramp
end temperature setpoint of last segment even when the program operation is
finished.
If it is disabled, temperature would be no longer under control as shaking motion
stops.
To switch this function, follow the below steps,
Press "Stop" button in the home page to stop the current operation.
Enter "FUNC" page.
Press the "KEEP" to enable/disable the temperature holding function
6.3.3 LIGHT MODE-- Switch of Control Mode - Photosynthetic Lighting (Option)
When equipped with LED Photosynthetic Lighting, the lighting function can be set to
run under fixed value mode with fixed functional parameters settings, or under
programmable mode, with program up to 10 different segments, each with their own
Ramp Time, Ramp End Light Outputs, Hold Time, to simulate natural environment.
This function will enable or disable the photosynthetic lighting control system.
To switch this function, follow the below steps,
Press "Stop" button in the home page to stop the current operation.
Enter "FUNC" page.
Press the "LIGHT MODE" to switch the photosynthetic lighting control between
“FIXED” and “PROG” mode
Special Remind!
Make sure the unit is stopped (by pressing STOP) before changing the
state of CTRL MODE".