GATE 2
21
Security exit loop
Connecting scheme of
loop detector 1 reader
10 = Contact photocell
(n.c.)
11 = Common photocell
Security loop
Connecting scheme of
loop detector 2 reader
4 = Contact start (n.o.)
11 = Common
Free exit loop
Connecting scheme of loop
detector reader
4 = Contact start (n.o.)
11 = Common
Safety exit
loop 1
Loop1
Loop2
Loop3
10 11 12 13 14 15 16 17
1 2 3 4 5 6 7 8 9
-
+
C1
CN2
C2
--
DRAWING SHOWS HOW TO
EVENTUALLY CONNECT THE
MAGNETIC LOOP
Safety
loop 2
Free exit
loop 3
SAFETY LOOP CONNECTION
International registered trademark n. 2.777.971
REV 05 - 10/2010
C1 = CONTACT OPEN
C2 = CONTACT CLOSED
15 = 24 V
11 = 0 V