Section 6: Troubleshooting and Maintenance
Troubleshooting
2016 Bambi MAX Service Manual Models 1518-3542 (Version E) 25
We Engineer Solutions
Section 6: Troubleshooting and Maintenance
Troubleshooting
Valve Troubleshooting
Problem Status Lamp Possible Cause Solution
Circuit breaker tripped Reset circuit breaker.
No Power Off (W hite)
Aircraft / longline wiring
Check aircraft / longline
wiring.
Aircraft / longline wiring
Check aircraft / longline
wiring.
Mechanical jamb Clear jamb / check linkage
Valve adjusted too high Adjust valve down.
Circuit Breaker
Trips
Off (W hite)
Valve adjusted too low Adjust valve up.
Flashing
Green
Motor protector
activated
Power cycle to reset.
Adjust valve up.
No open signal
Check aircraft / longline
wiring.
Yellow
Controller failure Contact service center.
Green Damaged drive cable Replace drive cable.
Valve Closed
Won't Open
Red
Controller / sensor
failure
Contact service center.
Flashing
Green
Motor protector
activated
Power cycle to reset.
Adjust valve down.
Green Controller failure Contact service center.
Yellow Damaged drive cable Replace drive cable.
Valve Open
Won't Close
Red
Controller / sensor
failure
Contact service center.
Damaged seals Replace seals.
Valve Leaks Yellow
Valve adjusted too high Adjust valve down.

Table of Contents

Other manuals for SEI Industries BAMBI MAX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SEI Industries BAMBI MAX and is the answer not in the manual?

SEI Industries BAMBI MAX Specifications

General IconGeneral
BrandSEI Industries
ModelBAMBI MAX
CategoryControl Unit
LanguageEnglish

Related product manuals