EasyManua.ls Logo

SEI Industries BAMBI MAX - Bambi MAX Maintenance and Troubleshooting; Valve Troubleshooting

Default Icon
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 6: Troubleshooting and Maintenance
Troubleshooting
2016 Bambi MAX Service Manual Models 1518-3542 (Version E) 25
We Engineer Solutions
Section 6: Troubleshooting and Maintenance
Troubleshooting
Valve Troubleshooting
Problem Status Lamp Possible Cause Solution
Circuit breaker tripped Reset circuit breaker.
No Power Off (W hite)
Aircraft / longline wiring
Check aircraft / longline
wiring.
Aircraft / longline wiring
Check aircraft / longline
wiring.
Mechanical jamb Clear jamb / check linkage
Valve adjusted too high Adjust valve down.
Circuit Breaker
Trips
Off (W hite)
Valve adjusted too low Adjust valve up.
Flashing
Green
Motor protector
activated
Power cycle to reset.
Adjust valve up.
No open signal
Check aircraft / longline
wiring.
Yellow
Controller failure Contact service center.
Green Damaged drive cable Replace drive cable.
Valve Closed
Won't Open
Red
Controller / sensor
failure
Contact service center.
Flashing
Green
Motor protector
activated
Power cycle to reset.
Adjust valve down.
Green Controller failure Contact service center.
Yellow Damaged drive cable Replace drive cable.
Valve Open
Won't Close
Red
Controller / sensor
failure
Contact service center.
Damaged seals Replace seals.
Valve Leaks Yellow
Valve adjusted too high Adjust valve down.

Table of Contents

Other manuals for SEI Industries BAMBI MAX

Related product manuals