Section 6: Troubleshooting and Maintenance
Troubleshooting
2016 Bambi MAX Service Manual Models 1518-3542 (Version E) 27
We Engineer Solutions
PowerFill Snorkel Troubleshooting
Problem Possible Cause Solution
Circuit breaker tripped. Reset circuit breaker.
Disconnected cable. Check cable connections.
Pump Won't Run
Incompatible power supply.
Compare power supply output with pump
requirements.
Debris jamming pump. Remove debris.
Circuit Breaker Trips
Damaged motor. Replace motor.
No Water Flow Motor running backwards. Check cable connections.
Pump impeller worn or damaged. Repair / replace pump impeller.
Pump Noisy
Debris in impeller housing. Remove debris.
Debris filter clogged. Clean debris filter.
Pump impeller worn or damaged. Repair / replace pump impeller.
Excessive voltage drop in longline. Use larger gauge cables.
Fill Times Excessive
Damage to cables. Repair / replace cables.