Frequency | 50/60 Hz |
---|---|
Mounting | Panel Mount |
Accuracy | ±0.2% FS |
Sampling Rate | 1 second |
Communication | RS485 (Modbus RTU) |
Protection | IP65 |
Storage Temperature | -20°C to 70°C |
Details the physical dimensions required for mounting the HMI unit into an opening.
Describes the physical connections for the HMI's various ports and terminals on the back.
Explains the pinout and connection types for RS232 and RS485 ports, including remarks.
Introduces supported communication protocols like PPI, MPI, Modbus, and Siemens.
Details communication for COM1 (RS485) and COM2 (RS232) interfaces with supported devices.
Details communication protocols supported over the Ethernet interface, like Modbus TCP.
Provides connection diagrams for various PLCs like Siemens, Mitsubishi, and Panasonic.
Explains the purpose and general principles of address setting for PLC communication.
Defines register names, formats, and ranges for S7-200 communication.
Defines register names, formats, and ranges for S7-300 communication.
Defines register names, formats, and ranges for MODBUS communication.
Details register names, formats, and ranges for Mitsubishi FX series.
Details register names, formats, and ranges for Panasonic Fp series.
Details register names, formats, and ranges for Omron CP1H.
Explains how to search and replace internal and external addresses within the project.
Introduces features for dynamic visual elements like pictures, graphs, and shapes on the HMI.
Details how to set up static image displays controlled by addresses or time.
Details how to set up animated GIF displays for dynamic content.
Explains how to configure bar graphs for visualizing data values.
Details how to simulate liquid flow status with animated blocks.
Explains configuration of dynamic rectangles and circles based on data.
Explains the concept of recipes for managing production process variables.
Demonstrates creating and managing recipes for product formulation with ingredients.
Outlines steps to create recipe groups and set ingredient proportions.
Explains data exchange between external devices and the HMI.
Details how to configure data transmission entries, including source and destination.
Explains how the system handles and records abnormal events during operation.
Details how to set up alarm triggers, event content, and display parameters.
Explains how alarms are displayed and managed on the system and across pages.
Details how to query and manage historical alarm records via function buttons.
Explains the feature for supporting multiple languages in the HMI interface.
Details how to set up and switch between languages using function buttons.
Explains recording, displaying, and downloading historical data.
Details configuration for collecting historical data, including sampling methods.
Explains how to add components for displaying historical data on the scene.
Details how to set up charts for visualizing historical data trends.
Explains how to protect user permissions and control access to components.
Describes default user settings and initial encryption setup for access control.
Details user level control for accessing specific components on the HMI.
Explains how to change user passwords and modify user permission levels.
Explains using USB to update HMI program and firmware versions.
Details the steps for updating HMI firmware and configuration files via USB.
Explains how to generate and display QR codes on the HMI for information.
Details methods for creating QR codes with fixed information or from address variables.
Explains HMI as a master communicating with multiple slave devices.
Illustrates basic communication setups with multiple devices like PLCs and HMIs.
Explains functions for managing system time and synchronizing with PLC.
Details how to transfer system time settings from the project to the HMI.
Explains how to write HMI time settings to the PLC, with or without real-time clock.
Details how to synchronize HMI and PLC time settings for consistency.
Explains time-limited HMI usage and unlock procedures via password.
Details how to configure time-based access restrictions and passwords.
Explains managing password levels and stage times for installment payment.
Explains support for ladder logic control and programming in ATSEL software.
Details how to map and edit addresses for ladder logic programming.
Guides through initial HMI startup and system configuration.
Explains how to view system version, storage space, and IP address.
Details how to set the IP address for Ethernet communication.
Explains the purpose and use of internal system registers for control.
Details how to enable and configure printing for HMI data.
Explains how to print historical data with time and date options.
Details how to enable automatic printing of alarm data.
Explains setting the baud rate and port for printer communication.
Provides information on the printer model WH-E45 and its connection.
Details the specific wiring connections for HMI serial ports to the printer.