EasyManua.ls Logo

Selec SP112 Series

Selec SP112 Series
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ATSEL HMI User Manual
ATSEL HMI User
Manual
(Version
2.02)
Selec Controls Pvt. Ltd.
Question and Answer IconNeed help?

Do you have a question about the Selec SP112 Series and is the answer not in the manual?

Selec SP112 Series Specifications

General IconGeneral
Frequency50/60 Hz
MountingPanel Mount
Accuracy±0.2% FS
Sampling Rate1 second
CommunicationRS485 (Modbus RTU)
ProtectionIP65
Storage Temperature-20°C to 70°C

Summary

Installation

Dimension for Installation Opening

Details the physical dimensions required for mounting the HMI unit into an opening.

Interface Connection

Describes the physical connections for the HMI's various ports and terminals on the back.

COM Port Connection

COM Port Configuration Details

Explains the pinout and connection types for RS232 and RS485 ports, including remarks.

Communication Protocol

Protocol Overview

Introduces supported communication protocols like PPI, MPI, Modbus, and Siemens.

Series Communication Details

Details communication for COM1 (RS485) and COM2 (RS232) interfaces with supported devices.

Ethernet Communication

Details communication protocols supported over the Ethernet interface, like Modbus TCP.

PLC Connectivity Examples

Provides connection diagrams for various PLCs like Siemens, Mitsubishi, and Panasonic.

Address Setting

Function Introduction for Addressing

Explains the purpose and general principles of address setting for PLC communication.

RS485 Siemens S7-200 PPI Addressing

Defines register names, formats, and ranges for S7-200 communication.

RS485 Siemens S7-300 MPI Addressing

Defines register names, formats, and ranges for S7-300 communication.

MODBUS Addressing Details

Defines register names, formats, and ranges for MODBUS communication.

Mitsubishi FX Series Addressing

Details register names, formats, and ranges for Mitsubishi FX series.

Panasonic Fp Series Addressing

Details register names, formats, and ranges for Panasonic Fp series.

Omron CP1 H Addressing

Details register names, formats, and ranges for Omron CP1H.

Address Searching Function

Explains how to search and replace internal and external addresses within the project.

Animation Design

Function Introduction for Animation

Introduces features for dynamic visual elements like pictures, graphs, and shapes on the HMI.

Picture Display Configuration

Details how to set up static image displays controlled by addresses or time.

GIF Display Configuration

Details how to set up animated GIF displays for dynamic content.

Bar Graph Display Configuration

Explains how to configure bar graphs for visualizing data values.

Flow Block Simulation Setup

Details how to simulate liquid flow status with animated blocks.

Dynamic Shapes Configuration

Explains configuration of dynamic rectangles and circles based on data.

Recipe Function

Function Introduction for Recipes

Explains the concept of recipes for managing production process variables.

Recipe Management Example

Demonstrates creating and managing recipes for product formulation with ingredients.

Recipe Achievement Steps

Outlines steps to create recipe groups and set ingredient proportions.

Data Transmission

Function Introduction for Data Transmission

Explains data exchange between external devices and the HMI.

Data Transmission Setup Procedure

Details how to configure data transmission entries, including source and destination.

Alarm

Function Introduction for Alarms

Explains how the system handles and records abnormal events during operation.

Alarm Settings and Trigger Conditions

Details how to set up alarm triggers, event content, and display parameters.

Real-time and System Alarm Display

Explains how alarms are displayed and managed on the system and across pages.

Historical Alarm Data

Historical Alarm Data Query and Management

Details how to query and manage historical alarm records via function buttons.

Multilingual Settings

Function Introduction for Multilingual

Explains the feature for supporting multiple languages in the HMI interface.

Language Switching and Example

Details how to set up and switch between languages using function buttons.

Historical Data Record

Function Introduction for Historical Data

Explains recording, displaying, and downloading historical data.

Historical Data Collection Setup

Details configuration for collecting historical data, including sampling methods.

Historical Data Display Setup

Explains how to add components for displaying historical data on the scene.

Historical Trend Chart Configuration

Details how to set up charts for visualizing historical data trends.

User Encryption

Function Introduction for User Encryption

Explains how to protect user permissions and control access to components.

Project Initial User Setting

Describes default user settings and initial encryption setup for access control.

Advanced Component User Settings

Details user level control for accessing specific components on the HMI.

Password and Level Modification

Explains how to change user passwords and modify user permission levels.

Update Program by U Disk

Function Overview for U Disk Update

Explains using USB to update HMI program and firmware versions.

U Disk Update Procedure Example

Details the steps for updating HMI firmware and configuration files via USB.

QR Code Display

Function Introduction for QR Code

Explains how to generate and display QR codes on the HMI for information.

QR Code Generation Methods

Details methods for creating QR codes with fixed information or from address variables.

Multi-device Connection

Function Introduction for Multi-device

Explains HMI as a master communicating with multiple slave devices.

Minimum Communication Combination Examples

Illustrates basic communication setups with multiple devices like PLCs and HMIs.

Time Setup

Function Introduction for Time Setup

Explains functions for managing system time and synchronizing with PLC.

Download System Time to HMI

Details how to transfer system time settings from the project to the HMI.

Write Time to PLC

Explains how to write HMI time settings to the PLC, with or without real-time clock.

Time Synchronization with PLC

Details how to synchronize HMI and PLC time settings for consistency.

Installment Payment

Function Introduction for Installment Payment

Explains time-limited HMI usage and unlock procedures via password.

Deadline Protection Settings

Details how to configure time-based access restrictions and passwords.

Installment Payment Management

Explains managing password levels and stage times for installment payment.

Ladder Chart

Function Introduction for Ladder Chart

Explains support for ladder logic control and programming in ATSEL software.

Ladder Address Mapping and Editing

Details how to map and edit addresses for ladder logic programming.

System Setup

Function Instruction for System Setup

Guides through initial HMI startup and system configuration.

System Information and Storage View

Explains how to view system version, storage space, and IP address.

IP Address Configuration

Details how to set the IP address for Ethernet communication.

Internal Register of the System

Function Introduction for System Registers

Explains the purpose and use of internal system registers for control.

Printing Function

Printer Setup and Options

Details how to enable and configure printing for HMI data.

Historical Data Printing

Explains how to print historical data with time and date options.

Alarm Data Printing

Details how to enable automatic printing of alarm data.

Print Parameter Setting

Baud Rate and Port Configuration

Explains setting the baud rate and port for printer communication.

Printer Connection

Printer Model and Wiring Details

Provides information on the printer model WH-E45 and its connection.

Series Port Wiring Instructions

Details the specific wiring connections for HMI serial ports to the printer.