SELECT GATE SG-1A V1.X INSTALLATION AND USER GUIDE
22
2 5
6
2 3
7
1
3
2
4.2.7 STRIKE OUT COUNT (Function 26)
Strike out count is the number of times from 1 to 9 an incorrect PIN code can be entered
before lock out occurs. This means that Select Gate will no longer respond to keypad input, until
the lock out time expires. The lock out length of time is from 1 to 4 minutes.
To change the strike out count from the default of 3 strikes to 5 strikes:
4.2.8 LOCK OUT TIME (Function 27)
Lock out time is the time in minutes from 1 to 4 minutes that the keypad does not respond
to key presses. This is to keep the PIN codes from being "guessed".
To change the lock out time from the default of 1 minute to 3 minutes:
4.2.9 RELAY 2 UNLOCK TONE (Function 31)
This is the Touch-Tone™ number that the house would press in order to activate the
optional relay 2 on the Select Gate for the programmed unlock time. This time is from 1 to 99
seconds. Any single Touch-Tone™ from 1 through 9 may be used to energize relay 2. Touch-
Tone™ 0 is used to disable functions on the Select Gate.
To change from the default of 0 (disabled) to 2:
NOTE: IF THE SAME TOUCH-TONE™ NUMBER IS USED FOR RELAY 1
AND RELAY 2, BOTH RELAYS WILL ENERGIZE AT THE SAME TIME.
4.2.10 RELAY 2 LATCH TONE (Function 32)
This is the Touch-Tone™ number that the house would press, after calling the Select Gate and
entering the 2 digit control password, in order to activate relay 2 on the Select Gate for unlimited time.
Any single Touch-Tone™ from 1 through 9 may be used to energize relay 2. Touch-Tone™ 0 is used to
disable functions on the Select Gate.
To change from the default of 0 (disabled) to 5: