BISS Service Not Found
Service that BISS key is assigned to descramble is not present in
the incoming stream.
Backup Input Active
Condition
Primary input is currently in a failed condition and the MRD 5800
has failed over to the Backup input.
Bitrate Exceeded Error
Total incoming transport stream bitrate has exceeded 213 Mbps.
CAM Descramble Fail
CAM Module is not descrambling selected pids or services
CAM Not Present
DVB-CI Descrambling is enabled but CAM Module is not
installed.
CAM PID Not Found
PID selected to be descrambled by the CAM is not present in the
incoming stream.
ES Type Mismatch
Elementary stream type does not match the stream type defined
by the user.
FEC Reception Error
Packets in incoming IP stream cannot be repaired with forward
error correction.
Fan Speed Below Lower
Limit
Cooling fan in the MRD 5800 has failed.
Genlock Not Present
Genlock reference is enabled but not present.
IP Loss Error
No IP packets have been received by the MPEG/IP card for two
seconds.
ISI Not Found
ISI value defined by the user is not found in the incoming
multistream signal.
Incompatible Genlock
Reference
External genlock reference is not compatible with output video
format.
Input Video Unsupported
Native format of incoming video is not a supported video format.
LNB Power Error
LNB Power is enabled but the MRD 5800 is detecting power is
being provided by another source, there is excessive current
drain or an overvoltage has occurred.
Link Loss Error
Physical IP link is not present on the MPEG/IP card.
Loss of Carrier Lock
Receiver carrier lock source is lost.
Low Level
8VSB/QAM RF Level is below the user settable threshold
Low Mer
8VSB/QAM MER is below the user settable threshold
Multistream Mode Input
Mismatch
Multistream Mode is enabled and input signal is not multistream
capable or Multistream Mode is disabled and input signal is
multistream capable.
No Services Detected
Service Lock service selection mode is enabled but no services
are present in the active input transport stream.
Pid Filter Overflow Error
Configured PID Filter TS rate is too low.
Pid Filter Selection Not
Present
Selected Service or PID is not present for inclusion in the output
PID filter TS.
Power Supply Error
Power is lost to one of the Redundant Power Supplies
RDD11 Overflow
RDD11 data cannot fit into the VANC embedding line selected.
RTP Reception Error
Uncorrectable out of order or duplicate packets are present in

Table of Contents

Other manuals for Sencore MRD 2600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sencore MRD 2600 and is the answer not in the manual?

Sencore MRD 2600 Specifications

General IconGeneral
BrandSencore
ModelMRD 2600
CategoryReceiver
LanguageEnglish

Related product manuals