Timeout
The user settable time limit has been exceeded between
SCTE35 messages.
One of the in-use elementary streams is not synchronized to the
PCR
Present
PID Locked mode is set as service selection mode and audio PID
defined by user is not present in the incoming stream.
Present
PID Locked mode is set as service selection mode and PCR PID
defined by user is not present in the incoming stream.
Present
PID Locked mode is set as service selection mode and SCTE35
PID defined by user is not present in the incoming stream.
Present
PID Locked mode is set as service selection mode and video PID
defined by user is not present in the incoming stream.
Service Lock service selection mode is enabled but service
defined by user is not present in the incoming stream.
The MRD 5800 has detected the internal temperature is 60
degrees Celsius or above.
Transport Error Indicator
The MRD 5800 has detected that the transport stream error
indicator is present on the active input.
Present
The MRD 5800 has detected that the transport stream from the
active input is no longer present.
Transport stream sync for IP stream is not detected.
Found Error
The MRD 5800 cannot discover the destination for the unicast IP
stream within 10 seconds after the initial ARP is sent.
Input stream on active input is either 16APSK or 32APSK and the
modulations are no licensed on the MRD 5800.
VCM/Multistream
Input stream on the active input contains a multistream signal
and the MRD 5800 is not licensed for multistream.
The configured service or video PID to be decoded is not being
successfully decoded by the MRD 5800.