8.7 Mainenance Plan
The following notes refer to regular usage situation.
Under special conditions, such as long daily working times, the maintenance
intervals stated must be reduced accordingly.
Perform maintenance work at regular intervals.
Charge a specialist workshop authorized by us if you cannot perform all work on
your own.
The owner of the power tool is also responsible for:
• Damage from unprofessional or belated maintenance or repair work
• Subsequent damage
– also corrosion – in case of improper storage
Once after 5 operating hours
Before and during each working operation
Weekly
Every 50 operating hours
Every 100 operating hours
On demand
At start-up / annually
Cooling air openings in the
starter housing
Clean X X
Carburetor
Chap. 8.3, page 28
Check idling X
Set idling (screw “T”) X
Set carburetor (screws “L”/”H”)
(for specialist workshops only)
X
Airlter
Chap. 8.4, page 29
Interimemptyingoftheairlters X X
Cleanairlterthoroughly X X
Replace X
Screenlterofthewatersup-
ply line
Chap. 8.2, page 28
Clean X X
Spark plug
Chap. 8.5, page 30
Checkrmseatofignitioncableandspark
plug connector
X X
Check electrode distance and replace spark
plug if required
X X
Replace X X
All screws in reach
(except for adjustment screws)
Re-tighten X X X
Operating units
(stop button/switch, throttle control,
throttle control lock, starter)
Check function X
Entire power tool Visual condition inspection
•
Checkcutoffwheelandmuferfordamage.
• Check tank cap for tightness
X
• Check ribbed belt tension
chap. 5.6, page 19
X
Clean X X X
SENCORE S8100 CUT-OFF SAW MANUAL 33