EasyManua.ls Logo

senseFly eBee - Page 139

senseFly eBee
166 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Pitot malfunction A high airspeed was detected while on the ground.
User action: Be sure to protect the drone from the
wind and re-connect the battery. If the problem per-
sists, perform Check 4 in section ‘Full airframe and
sensor inspection’ on page 131. If this does not solve
the problem contact your eBee reseller.
High current A too high current was detected, which may be
caused by an internal problem.
User action: Re-connect the battery. If the problem
occurs twice, contact your eBee reseller.
Magnetometer
malfunction
There is an error with the drone’s magnetic field sen-
sor.
User action: Re-connect the battery. If the problem
persists, contact your eBee reseller.
EEPROM
malfunction
There is an error with the memory chip of the drones
autopilot.
User action: Re-connect the battery. If the problem
persists, contact your eBee reseller.
Barometer
malfunction
There is an error with the drones barometer.
User action: Be sure to place the drone on a flat
surface, reconnect the battery and do not move the
drone until pre-flight checks are complete. If the
problem persists, perform Check 3 in section ‘Full air-
frame and sensor inspection’ on page 131. If this
does not solve the problem contact your eBee re-
seller.
139

Table of Contents

Related product manuals