EasyManua.ls Logo

Sewhacnm SI 4100 - Function Settings; STEADY Judging ON Time; DRIB Control Application; Weight Mode and Manual Discharge Selection

Sewhacnm SI 4100
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Digital Weighing Indicator
SI 4100
- 36 -
“STEADY” Judging “ON” time(t4) setting (Only for F21-03, Check mode1.)
F25
10
00
∫
99
You can set duration time for Error relay
“01” setting : ERROR relay will be “ON during 0.1sec.
“20” setting : ERROR relay will be “ON” during 2.0sec.
“DRIB” Control Apply selection (Only for F21-02, F21-09)
F26
●
0
Not use
1
Use
Weight Mode selection
F27
●
0
Absolute weight weighing mode
1
Positive weight weighing mode
Manual Discharge selection (Only for F21-02, Packer mode)
F28
●
0
Not use
1
Use
■ Communication Mode setting (Serial Port 1. - Standard installed port)
Parity Bit selection Mode
F30
●
0
No Parity
1
Odd Parity
2
Even Parity
Serial Communication Speed selection
F31
0
2,400bps
1
4,800bps
●
2
9,600bps
3
14,400bps
4
19,200bps
5
28,800bps
6
38,400bps
7
57,600bps
Com-Out5
Steady point
t4

Table of Contents