: Feb. 9 2004
1
AR-M550/M620/M700 SIMULATION 8 - 23
Operation/Procedure
The operating conditions of the sensors and detectors are displayed.
The active sensors and detectors are highlighted.
Operation/Procedure
1) Select the number corresponding to the target of operation check
with 10-key.
2) Press [START] key.
The load selected in procedure 1 is operated.
Press [CUSTOM SETTINGS] key to stop the operation of the load.
Operation/Procedure
1) Select the number corresponding to the adjustment item with 10-
key.
2) Press [START] key.
3) Enter the setting (adjustment) value with 10-key.
4) Press [START] key.
5 Punch hole position adjustment
(Paper feed direction)
35 - 57, 1STEP: 0.26mm
6 Stack tray standby position
adjustment (Small size)
5 - 35, 1STEP: 1mm
7 Stack tray standby position
adjustment (Large size)
5 - 35, 1STEP: 1mm
Press [START] key, and the operation
is started.
Press [CUSTOM SETTINGS] key, and the
operation is stopped.
3-30
Purpose Operation test/Check
Function
(Purpose)
Used to check the operations of the sensors and
detectors in the inserter.
Section Inserter
Item
TH_SEN Sub tray pull-out detection
TS_SEN Sub tray storage detection
T_SEN Inserter tray paper size detection
EMP_SEN Inserter tray empty detection
REG_SEN Inserter resist sensor
TIM_SEN Inserter timing sensor detection
JCK_SEN Inserter cover open/close sensor
H_SEN Inserter reverse sensor
HI_SEN Inserter paper exit sensor
HYK_SEN Inserter reverse unit open/close sensor
S_SW Inserter set SW
KC_SEN Base cover open/close sensor
P_ST_SW Inserter start SW
P_MO_SW Inserter staple mode select SW
P_PN_SW Inserter punch select SW
Item Set range
SIMULATION 3-10
FINISHER SETTING. SELECT 1-7
AND PRESS START.
1. SADDLE POSITION
2. ALIGNMENT POSITION
3. STAPLE POSITION
4. PUNCH CENTER
5. PUNCH HOLE
6. TRAY WAITING POSITION(S-SIZE)
7. TRAY WAITING POSITION(L-SIZE)
1
SIMULATION 3-10
CONSOLE FINISHER SETTING. INPUT VALUE, AND PRESS START.
1. SADDLE POSITION
200
SIMULATION 3-30
INSERTER SENSOR CHECK.
TH_SEN TS_SEN T_SEN EMP_SEN
REG_SEN TIM_SEN JCK_SEN H_SEN
HI_SEN HYK_SEN S_SW KC_SEN
P_ST_SW P_MO_SW P_PN_SW
3-31
Purpose Operation test/Check
Function
(Purpose)
Used to check the operations of the loads in the
inserter and the related circuits.
Section Inserter
Item Operation
1 K_MOT Reverse motor
2 Y_MOT Horizontal transport motor
3 H_MOT Inserter reverse
4 F_SOL Inserter flapper solenoid
5 R_CL Inserter resist clutch
6 P_LED Inserter operation panel upper LED
Press [START] key, and the operation
is started.
Press [CUSTOM SETTINGS] key, and the
operation is stopped.
3-32
Purpose Setting (Adjustment)
Function
(Purpose)
Inserter paper width detection level setting.
Section Inserter
Item Operation
1 MAX. POSITION Max. position
2 POSITION 1 Adjustment point 1
3 POSITION 2 Adjustment point 2
4 MIN. POSITION Min. width
Press [START] key. Press [CUSTOM SETTINGS] key.
SIMULATION 3-31
INSERTER LOAD TEST. SELECT 1-6, AND PRESS START.
1. K_MOT 2. Y_MOT 3. H_MOT
4. F_SOL 5. R_CL 6. P_LED
2
SIMULATION 3-31
INSERTER LOAD TEST. EXECUTING
...
.
2. Y_MOT
2
1
SIMULATION 3-32
INSERTER TRAY VALUE SETTING. SELECT 1-4, AND PRESS
START.
1. MAX. POSITION : 72
2. POSITION 1 : 380
3. POSITION 2 : 710
4. MIN. POSITION : 804
SIMULATION 3-32
INSERTER TRAY VALUE SETTING. INPUT VALUE 0-1023, AND
PRESS START.
1. MAX. POSITION
72