Loading...
: Feb. 9 2004
1
AR-M550/M620/M700 SIMULATION 8 - 24
Operation/Procedure
The operating conditions of the sensors and detectors are displayed.
The active sensors and detectors are highlighted.
<LCC>
Operation/Procedure
1. Select the number corresponding to the target of operation check
with 10-key.
2. Press [START] key.
The load selected in procedure 1 is operated.
Press [CUSTOM SETTINGS] key to stop the operation of the load.
<Side LCC>
Operation/Procedure
The LCD is changed as shown below. (The contrast changes every
2sec from the current level to MAX
MIN
the current level. During
this period, each LED is lighted.
Operation/Procedure
1) Select the number corresponding to the target of operation check
with 10-key.
2) Press [START] key.
The load selected in procedure 1 performs ON/OFF operation.
Press [CUSTOM SETTINGS] key to stop the operation of the load.
The ON/OFF operation of the selected heater lamp is repeated
every 500ms five times.
4
4-2
Purpose Operation test/Check
Function
(Purpose)
Used to check the operations of the sensors and
detectors in the paper feed section (large capacity tray)
and the related circuit.
Section Paper feed
Item Operation
LTD Transport sensor
LUD Tray upper limit sensor
LLD Tray lower limit sensor
LPED Tray paper presence/empty sensor
LTOD Main unit connection detection sensor
LCD Tray insertion detection
LOSW Upper open/close detection SW
LRE Lift motor encoder sensor
+24VM 24V power monitor
LLSW Upper limit SW
4-3
Purpose Operation test/Check
Function
(Purpose)
Used to check the operations of the loads in the paper
feed section (large capacity tray) and the related
circuit.
Section Paper feed
Item Operation
1 LTM LCC transport motor
2 LLM LCC lift motor
3 LPFCL Paper feed clutch
4 LPSL LCC paper feed clutch
5 LTCL LCC transport clutch
6 LTLSL Tray lock solenoid D
Press [START] key, and the operation
is started.
Press [CUSTOM SETTINGS] key, and the
operation is stopped.
SIMULATION 4-2
LCC SENSOR CHECK.
LTD LUD LLD LPED
LCD LOSW LRE +24VM
LLSW
SIMULATION 4-3
LCC LOAD TEST. SELECT 1-6, AND PRESS START.
1.LTM 2.LLM
3.LPFCL 4.LPSL
5.LTCL 6.LTLSL
2
SIMULATION 4-3
LCC LOAD TEST. EXECUTING
...
.
1. LTM 2. LLM
3. LPFCL 4. LPSL
5. LTCL 6. LTLSL
2
5
5-1
Purpose Operation test/Check
Function
(Purpose)
Used to check the operation of the display, LCD in the
operation panel, and control circuit.
Section Operation (Display/Operation key)
Item Operation
After 6.0sec Press [CUSTOM SETTINGS] key,
and the operation is stopped.
5-2
Purpose Operation test/Check
Function
(Purpose)
Used to check the operation of the heater lamp and the
control circuit.
Section Fixing (Fusing)
Item Operation
1 HL1 (LOWER) Heater lamp 1 (Lower)
2 HL2 (UPPER) Heater lamp 2 (Upper)
3 HL3 (LEFT) Heater lamp 3 (Left)
Press [START] key, and the operation
is started.
Press [CUSTOM SETTINGS] key, and the
operation is stopped.
The operation is repeated the specified
number of times before stopping.
SIMULATION 5-1
SIMULATION 5-1
SIMULATION 5-2
HEATER LAMP TEST. SELECT 1-3 ,AND PRESS START.
1.HL1(LOWER)
2.HL2(UPPER)
3.HL3(LEFT)
2
SIMULATION 5-2
HEATER LAMP TEST. EXECUTING···.
1.HL1(LOWER)
2.HL2(UPPER)
3.HL3(LEFT)
2