AR-M550/M620/M700 SIMULATION 8 - 75
Operation/Procedure
1) Set the SPF paper feed guide to the max. position.
2) Select "MAX. POSITION" with 10-key.
3) Press [START] key.
The max. width detection level is recognized.
4) Press [CSUTOM SETTING] key.
5) Set the SPF paper feed guide to A4R size position.
6) Select POSITION 1 with 10-key.
7) Press [START] key.
The A4R width detection level is recognized.
8) Press [CSUTOM SETTING] key.
10) Select POSITION 2 with 10-key.
11) Press [START] key.
12) Press [CSUTOM SETTING] key.
13) Set the SPF paper feed guide to the min. position.
14) Select "MIN. POSITION" with 10-key.
15) Press [START] key.
The min. width detection level is recognized.
If the above procedures are not completed normally, ERROR is dis-
played. When completed normally, COMPLETE is displayed.
Operation/Procedure
1) Enter the number corresponding to the set item with 10-key.
2) Press [START] key.
3) Enter the set value with 10key.
4) Press [START] key.
Select 0, and
press [START] key.
Press [START] key, or
press [CUSTOM SETTINGS] key.
53
53-6
Purpose Adjustment
Function
(Purpose)
Used to adjust the DSPF width detection level.
Section
Item Operation
9) Set the SPF paper feed guide to A5R size position.
The A5R width detection level is recognized.
50
1
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 0-14, AND PRESS START.
0.TRAY SELECT 1 1.PRINT START
2.TRAY1 46 3.TRAY2 45 4.TRAY3 46
5.TRAY4 46 6.BPT 45 7.LCC 45
8.ADU 43 9.SPF(TOP) 50 10.SPF(HIGH) 50
11.SPF(LOW) 50 12.SPF FEED(TOP) 50
13.SPF FEED(HIGH) 50 14.SPF FEED(LOW) 50
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. NOW PRINTING.
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
1.TRAY1
Select 1,
and press
[START] key.
Select other than 0 - 1, and
press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key,
or terminate copying.
1
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT 6.LCC
(ABOVE+10: DUPLEX MODE)
1
1
Select 4, and press [START] key. Press [CUSTOM SETTINGS]
key.
53-7
Purpose Adjustment/Setup/Operation data output/Check
(Display/Print)
Function
(Purpose)
Used to enter the SPF width detection adjustment
value.
Section DSPF
Item Operation
Item Set range Default
1 MAX. POSITION Max. width 0 - 1023 66
2 POSITION 1 Adjustment position 1 456
3 POSITION 2 Adjustment position 2 713
4 MIN. POSITION Min. width 791
Press [START] key. Press [CUSTOM SETTINGS] key.
1
Select 2, and press [START] key.
Select 3, and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1.MAX.POSITION
2.POSITION 1
3.POSITION 2
4.MIN.POSITION
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MAX.POSITION ... COMPLETE (or ERROR)
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 1 ... COMPLETE (or ERROR)
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 2 ... COMPLETE (or ERROR)
Select 1, and
press [START] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MIN.POSITION ... COMPLETE (or ERROR)
1
SIMULATION 53-7
SPF TRAY ADJUSTMENT(MANUAL). SELECT 1-4, AND PRESS
START.
1.MAX.POSITION: 66
2.POSITION 1 : 456
3.POSITION 2 : 713
4.MIN.POSITION: 791
66
SIMULATION 53-7
SPF TRAY ADJUSTMENT(MANUAL). INPUT VALUE 0-1023, AND
PRESS START.
1.MAX.POSITION