MX-M264U SIMULATION 6 – 30
27-4
Purpose
Setting
Function (Purpose)
Used to set the initial call and toner order
auto send. (FSS function)
Section
Operation/Procedure
1) Select an item to be set with scroll keys.
2) Enter the set value with 10-key.
3) Press [OK] key.
The set value in step 2) is saved.
27-5
Purpose
Setting
Function (Purpose)
Used to set the machine tag No. (This func-
tion allows the host computer to check the
machine tag No.) (FSS function)
Section
Communication (RIC/MODEM)
Operation/Procedure
1) Enter the password (max. 8 digits) with 10-key.
The entered password is displayed on the column of "NEW”.
In order to correct the entered password, press the [clear] key
to delete the entered value one digit by one digit.
2) Press [SET] key.
27-6
Purpose
Setting
Function (Purpose)
Used to set of the manual service call.
(FSS function)
Section
Operation/Procedure
1) Enter the set value with 10-key.
2) Press [OK] key.
The set value in step 1) is saved.
Item/Display Content
Setting
range
Default
value
Remarks
A FSS MODE NEB1 Set the FSS MODE Exclusive for send in NE-B mode 0 - 3 0 1
NEB2 Send/Receive in NE-B mode 1
NFB1 Exclusive for send in NE-F mode 2 For convenience
stores
NFB2 Send/Receive in NE-F mode 3 For convenience
stores
B RETRY_BUSY Resend number setting when busy 0 - 15 2 0: No retry
C TIMER(MINUTE)_BUSY Resend timer setting (minute) when busy 1 - 15 3
D RETRY_ERROR Resend number setting when error 0 - 15 1 0: No retry
E TIMER(MINUTE)_ERROR Resend timer setting (minute) when error 1 - 15 1
F FAX RETRY Resend number setting when FAX initial connection 0 - 15 2 Unit: Number of times
G TONER ORDER
TIMING(K)
EMPTY Toner order auto send
timing setting (K)
Empty 0 - 11 0 6
NEAR_END Near end 1
0.05 0.05 2
0.1 0.1 3
0.15 0.15 4
0.2 0.2 5
0.25 0.25 6
0.3 0.3 7
0.35 0.35 8
0.4 0.4 9
0.45 0.45 10
0.5 0.5 11
H TEMP HISTORY CYCLE Frequency of acquiring the temperature and humidity history 1 - 1440 60 Unit: min.
I LOG OUTPUT CAPACITY(PCU) Log output capacity 0 - 50 30 Unit: [KB]
0 Allow (Default)
1 Inhibit