EasyManua.ls Logo

Sharp MX-M314N - Page 104

Sharp MX-M314N
256 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MX-M264U SIMULATION 6 – 30
27-4
Purpose
Setting
Function (Purpose)
Used to set the initial call and toner order
auto send. (FSS function)
Section
Operation/Procedure
1) Select an item to be set with scroll keys.
2) Enter the set value with 10-key.
3) Press [OK] key.
The set value in step 2) is saved.
27-5
Purpose
Setting
Function (Purpose)
Used to set the machine tag No. (This func-
tion allows the host computer to check the
machine tag No.) (FSS function)
Section
Communication (RIC/MODEM)
Operation/Procedure
1) Enter the password (max. 8 digits) with 10-key.
The entered password is displayed on the column of "NEW”.
In order to correct the entered password, press the [clear] key
to delete the entered value one digit by one digit.
2) Press [SET] key.
27-6
Purpose
Setting
Function (Purpose)
Used to set of the manual service call.
(FSS function)
Section
Operation/Procedure
1) Enter the set value with 10-key.
2) Press [OK] key.
The set value in step 1) is saved.
Item/Display Content
Setting
range
Default
value
Remarks
A FSS MODE NEB1 Set the FSS MODE Exclusive for send in NE-B mode 0 - 3 0 1
NEB2 Send/Receive in NE-B mode 1
NFB1 Exclusive for send in NE-F mode 2 For convenience
stores
NFB2 Send/Receive in NE-F mode 3 For convenience
stores
B RETRY_BUSY Resend number setting when busy 0 - 15 2 0: No retry
C TIMER(MINUTE)_BUSY Resend timer setting (minute) when busy 1 - 15 3
D RETRY_ERROR Resend number setting when error 0 - 15 1 0: No retry
E TIMER(MINUTE)_ERROR Resend timer setting (minute) when error 1 - 15 1
F FAX RETRY Resend number setting when FAX initial connection 0 - 15 2 Unit: Number of times
G TONER ORDER
TIMING(K)
EMPTY Toner order auto send
timing setting (K)
Empty 0 - 11 0 6
NEAR_END Near end 1
0.05 0.05 2
0.1 0.1 3
0.15 0.15 4
0.2 0.2 5
0.25 0.25 6
0.3 0.3 7
0.35 0.35 8
0.4 0.4 9
0.45 0.45 10
0.5 0.5 11
H TEMP HISTORY CYCLE Frequency of acquiring the temperature and humidity history 1 - 1440 60 Unit: min.
I LOG OUTPUT CAPACITY(PCU) Log output capacity 0 - 50 30 Unit: [KB]
0 Allow (Default)
1 Inhibit

Table of Contents

Other manuals for Sharp MX-M314N

Related product manuals