MX-M264U SIMULATION 6 – 31
27-7
Purpose
Setting
Function (Purpose)
Used to set of the enable, alert callout.
(FSS function)
Section
Operation/Procedure
1) Select an item to be set with scroll keys.
2) Enter the set value with 10-key.
3) Press [OK] key.
The set value in step 2) is saved.
*1 Alert send timing
27-9
Purpose
Setting
Function (Purpose)
Used to set the paper transport time record-
ing YES/NO threshold value and shading
gain adjustment retry number.
(FSS function)
Section
Operation/Procedure
1) Select an item to be set with scroll keys.
2) Enter the set value with 10-key.
3) Press [OK] key.
The set value in step 2) is saved.
* Items A, B: 0%, standard passing time between sheets of paper;
100%, time for judgment as a jam between sheets of paper.
* Item C: Because of a trouble in shading operation, the number of
retry is actually not registered.
27-10
Purpose
Data clear
Function (Purpose)
Used to clear the trouble prediction history
information. (FSS function)
Section
Operation/Procedure
1) Press [EXECUTE] key.
2) Press [YES] key.
The history information of trouble prediction is cleared.
27-11
Purpose
Others
Function (Purpose)
Used to check the serial communication
retry number and the scanner gain adjust-
ment retry number history. (FSS function)
Section
Operation/Procedure
The serial communication retry number history and the scanner
gain adjustment retry number history are displayed.
Item/Display Content
Setting
range
Default
value
A FUNCTION
(0:YES 1:NO)
FSS function enable 0 1 (NO)
FSS function disable 1
BALERT
(0:YES 1:NO)
Alert call enable (*1) 0 0 (YES)
Alert call disable 1
C CONNECTION
(0: FAX
1: No Use
2: HTTP)
FAX connection enable 0 0 (FAX)
Not used. 1
HTTP connection enable 2
No alert cause Initial state / Trouble / Continuous JAM alert
Maintenance When the maintenance timing is reached.
Service call When pressing Service call.
Toner send request When the toner order automatic send setting is
reached.
Toner collection request Revision of the toner installation date (only for
a new product)
Alert resend
Item/Display Content
Setting
range
Default
value
A FEED TIME1 Threshold value of paper
transport time between
sensors (Machine)
0 - 100 50(%)
B FEED TIME2 Threshold value of paper
transport time between
sensors (SPF)
0 - 100 50(%)
CGAIN
ADJUSTMENT
RETRY
Threshold value of the gain
adjustment retry number
0 - 20 11
(TIMES)
D JAM ALERT Continuous JAM alert
judgment threshold value
(Alert judgment threshold
value for continuous JAM's)
(Setting of the number of
JAM's continuously made
at which it is judged as an
alert.)
1 - 100 10
(TIMES)
Target history Serial communication retry history
Scanner gain adjustment retry history
Paper transport time between sensors
Display Item
Content
Item name
Occurrence date
(Display)
Retry
number
LSU1 Year/month/day
hour: min.: sec.
8 digits Serial
communication
retry number
history display
LSU2 Year/month/day
hour: min.: sec.
8 digits
DESK1 Year/month/day
hour: min.: sec.
8 digits
DESK2 Year/month/day
hour: min.: sec.
8 digits
FINISHER1 Year/month/day
hour: min.: sec.
8 digits
FINISHER2 Year/month/day
hour: min.: sec.
8 digits
SCAN GAIN ADJ1 Year/month/day
hour: min.: sec.
8 digits Scanner gain
adjustment retry
history
SCAN GAIN ADJ2 Year/month/day
hour: min.: sec.
8 digits
SCAN GAIN ADJ3 Year/month/day
hour: min.: sec.
8 digits
SCAN GAIN ADJ4 Year/month/day
hour: min.: sec.
8 digits
SCAN GAIN ADJ5 Year/month/day
hour: min.: sec.
8 digits Scanner gain
adjustment retry
history