MX-M264U SIMULATION 6 – 35
41-3
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the docu-
ment size sensor and the control circuit.
Section
Operation/Procedure
The detection output level (A/D value) of OCSW and the document
sensor (PD1 - PD7) is displayed in real time.
The light receiving range of PD1 - PD7 is 1 - 255. (Default: 128)
43
43-1
Purpose
Setting
Function (Purpose)
Used to set the fusing temperature in each
mode.
Section
Operation/Procedure
1) Select an item to be set with scroll keys.
2) Enter the set value with 10-key.
3) Press [OK] key.
The set value in step 2) is saved.
26cpm machine
Item/Display Content Detection level range
OCSW Original cover SW 0-1 ("1" to Close)
PD1 Document detection 1 0 - 255
PD2 Document detection 2 0 - 255
PD3 Document detection 3 0 - 255
PD4 Document detection 4 0 - 255
PD5 Document detection 5 0 - 255
PD6 Document detection 6 0 - 255
PD7 Document detection 7 0 - 255
Item/Display Content
Setting
range
Default value
Group A Group B Group C Group D
SW-A SW-B SW-A SW-B SW-A SW-B SW-A SW-B
A HL_UM READY Ready standby TH_UM set value 70 - 220 175 175 175 175 180 180 180 180
B HL_US READY Ready standby TH_US set value 70 - 220 170 170 170 170 175 175 175 175
C HL_UM PLAIN PAPER BW Black-White plain paper TH_UM
set value
70 - 220 175 180 175 180 185 190 185 190
D HL_US PLAIN PAPER BW Black-White plain paper TH_US
set value
70 - 220 175 180 175 180 185 190 185 190
E WARMUP FUMON HL_UM T Fusing motor pre-rotation start
TH_US set value
0 - 20000000000
F WARMUP FUMOFF HL_UM T Fusing motor previous rotation
complete time
0 - 6000000000
G WARMUP END TIME Warm-up complete time 0 - 20 18 18 18 18 18 18 18 18
H HL_UM HEAVY PAPER Heavy paper TH_UM set value 70 - 220 190 190 190 190
I HL_US HEAVY PAPER Heavy paper TH_US set value 70 - 220 190 190 190 190
J HL_UM OHP PAPER OHP-TH_UM set value 70 - 220 175 175 185 185
K HL_US OHP PAPER OHP-TH_US set value 70 - 220 175 175 185 185
LHL_UM E-STAR Preheating TH_UM set value 70 - 2209595959595959595
MHL_US E-STAR Preheating TH_US set value 70 - 2209595959595959595
N HL_UM PRE-JOB TH_UM set value when recovery
from Warm-Up
70 - 220 130 175 175 175 175 175 175 175
O HL_UM WARMUP_120L TH_UM set value when Warm-Up
at 120ï‚°C or below
70 - 220 130 175 175 175 175 175 175 175
P HL_US WARMUP_120L TH_US set value when Warm-Up
at 120ï‚°C or below
70 - 220 130 170 170 170 170 170 170 170
Q LO_WARMUP_TIME O, P applying time (Timer from
completion of Ready)
0 - 25500000000
R HL_UM WARMUP_120H TH_LM set value when Warm-Up
at 120ï‚°C or above
70 - 220 130 175 175 175 175 175 175 175
S HL_US WARMUP_120H TH_US set value when Warm-Up
at 120ï‚°C or above
70 - 220 130 170 170 170 170 170 170 170