MX-M264U SIMULATION 6 – 38
Code descriptions
List of destination groups
P HL_US WARMUP_120L TH_US set value when Warm-Up
at 120ï‚°C or below
70 - 220 130 180 180 180 190 190 190 190
Q LO_WARMUP_TIME O, P applying time (Timer from
completion of Ready)
0 - 25500000000
R HL_UM WARMUP_120H TH_LM set value when Warm-Up
at 120ï‚°C or above
70 - 220 130 180 180 180 190 190 190 190
S HL_US WARMUP_120H TH_US set value when Warm-Up
at 120ï‚°C or above
70 - 220 130 180 180 180 190 190 190 190
T HI_WARMUP_TIME R, S applying time (Timer from
completion of Ready)
0 - 25500000000
U HI_WU_FM_ON_TMP FM prior rotation start TH_US
when Warm-Up at alpha ï‚°C or
above
0 - 22000000000
V HI_WU_END_TIME Warm-Up completion time when
Warm-Up at alpha ï‚°C or above
0 - 60 18 18 18 18 18 18 18 18
W HI_WU_JOB_SET_TMP 1 Job enable TH_UM temperature 1
when Warm-Up at alpha ï‚°C or
above
30 - 220 130 180 180 180 190 190 190 190
X HI_WARMUP_BORDER Threshold value alpha to which U -
W is applied
1 - 1196060606060606060
Y LO_WU_JOB_SET_TMP 1 Job enable TH_UM temperature 1
when Warm-Up at alpha ï‚°C or
below
70 - 220 130 180 180 180 190 190 190 190
Z JOBEND_FUMON_TIME After rotating time when a job is
completed
0 - 6000000000
AA HI_WU_JOB_SET_TMP 2 Job enable TH_UM temperature 2
when Warm-Up at alpha ï‚°C or
above
70 - 220 130 180 180 180 190 190 190 190
AB LO_WU_JOB_SET_TMP 2 Job enable TH_UM temperature 2
when Warm-Up at alpha ï‚°C or
below
70 - 220 130 180 180 180 190 190 190 190
Item/Display Content
Setting
range
Default value
Group A Group B Group C Group D
SW-A SW-B SW-A SW-B SW-A SW-B SW-A SW-B
TH_UM Fusing thermistor main (Front surface of paper) HL_UM Heater lamp main (Heat roller for front surface of paper)
TH_US Fusing thermistor sub (Front surface of paper) HL_US Heater lamp sub (Heat roller for front surface of paper)
SW-A Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
Group Destination
Group A JAPAN – – – –
Group B U. S. A CANADA INCH – –
Group C AB_B EUROPE U. K AUS. AB_A
Group DCHINA––––

Table of Contents