MX-M264U SIMULATION 6 – 39
43-4
Purpose
Setting
Function (Purpose)
Used to set the fusing temperature 2 in
each mode.
Section
Operation/Procedure
1) Select an item to be set with the scroll key.
2) Enter the set value with 10-key.
3) Press [OK] key.
The set value in step 2) is saved.
26cpm machine
Code descriptions
List of destination groups
31cpm machine
Item Display Content
Setting
range
Default value (SW-A) Default value (SW-B)
Group
A
Group
B
Group
C
Group
D
Group
A
Group
B
Group
C
Group
D
A HL_UM PLAIN PAPER BW
DUP
Black and white plain paper
duplex TH_UM set value
70 - 220 175 175 185 185 175 175 185 185
B HL_US PLAIN PAPER BW
DUP
Black and white plain paper
duplex TH_US set value
70 - 220 175 175 185 185 175 175 185 185
C PLAIN PAPER BW DUP
APP CNT
Black and white plain paper
duplex applying number of sheets
0 - 25500000000
D HL_UM HEAVY PAPER BW
DUP
Black and white heavy paper
duplex TH_UM set value
70 - 220 175 175 185 185 175 175 185 185
E HL_US HEAVY PAPER BW
DUP
Black and white heavy paper
duplex TH_US set value
70 - 220 175 175 185 185 175 175 185 185
F HEAVY PAPER BW DUP
APP CNT
Black and white heavy paper
duplex applying number of sheets
0 - 25500000000
TH_UM Fusing thermistor main (Front surface of paper) HL_UM Heater lamp main (Heat roller for front surface of paper)
TH_US Fusing thermistor sub (Front surface of paper) HL_US Heater lamp sub (Heat roller for front surface of paper)
SW-A Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
Group Destination
Group A JAPAN – – – –
Group B U. S. A CANADA INCH – –
Group C AB_B EUROPE U. K AUS. AB_A
Group DCHINA––––
Item Display Content
Setting
range
Default value (SW-A) Default value (SW-B)
Group
A
Group
B
Group
C
Group
D
Group
A
Group
B
Group
C
Group
D
A HL_UM PLAIN PAPER BW
DUP
Black and white plain paper
duplex TH_UM set value
70 - 220 185 190 195 195 185 190 195 195
B HL_US PLAIN PAPER BW
DUP
Black and white plain paper
duplex TH_US set value
70 - 220 185 190 195 195 185 190 195 195
C PLAIN PAPER BW DUP
APP CNT
Black and white plain paper
duplex applying number of sheets
0 - 25500000000
D HL_UM HEAVY PAPER BW
DUP
Black and white heavy paper
duplex TH_UM set value
70 - 220 185 190 195 195 185 190 195 195
E HL_US HEAVY PAPER BW
DUP
Black and white heavy paper
duplex TH_US set value
70 - 220 185 190 195 195 185 190 195 195
F HEAVY PAPER BW DUP
APP CNT
Black and white heavy paper
duplex applying number of sheets
0 - 25500000000