EasyManua.ls Logo

Sharp MX-M314N - Page 115

Sharp MX-M314N
256 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MX-M264U SIMULATION 6 – 41
43-10
Purpose
Setting
Function (Purpose)
Used to set the postcard feed cycle
Section
Operation/Procedure
1) Enter the set value with 10-key.
2) Press [OK] key. (The set value is saved.)
43-20
Purpose
Function (Purpose) Used to perform the low-temperature, low-
humidity (L/L) environment correction for
the fusing temperature setting of each
paper (SIM43-01).
Section
Operation/Procedure
1) Select an item to be set with the scroll key.
2) Enter the set value with 10-key.
3) Press [OK] key. (The set value is saved.)
* WARMUP END TIME LL: 1 count = 1s change
Other correction values: 1 count = 1ï‚°C change
* Items C/D: Correction of "–5" is made for item C and Item D in the case of B5 size
Item Display Content
Setting
range
Default
value
A POSTCARD CYCLE Postcard feed cycle 1 - 99 50
Item Display Content
Setting
range
Default
value
A HL_UM READY LL Correction value for TH_UM set value in ready standby under LL environment 1 - 99 55
B HL_US READY LL Correction value for TH_US set value in ready standby under LL environment 1 - 99 55
C HL_UM PLAIN BW LL Correction value for black and white plain paper TH_UM set value under LL environment 1 - 99 55
D HL_US PLAIN BW LL Correction value for black and white plain paper TH_US set value under LL environment 1 - 99 55
E WARMUP FUMON HL_US T LL Correction value for fusing motor previous rotation start TH_UM set value under LL environment 1 - 99 50
F WARMUP FUMOFF LL Fusing motor prior rotation completion time under LL environment 1 - 99 50
G WARMUP END TIME LL Correction value for warm-up complete time under LL environment 1 - 99 50
H HL_UM HEAVY LL Correction value for heavy paper TH_UM set value under LL environment 1 - 99 55
I HL_US HEAVY LL Correction value for heavy paper TH_US set value under LL environment 1 - 99 55
J HL_UM OHP LL Correction value for OHP-TH_UM set value under LL environment 1 - 99 55
K HL_US OHP LL Correction value for OHP-TH_US set value under LL environment 1 - 99 55
L HL_UM E-STAR LL Correction value for preheating TH_UM set value under LL environment 1 - 99 55
M HL_US E-STAR LL Correction value for preheating TH_US set value under LL environment 1 - 99 55
N HL_UM PRE-JOB LL Correction value for the set value of TH_UM when restoring from preheating under LL
environment
1 - 99 50
O HL_UM WARMUP_120L LL Correction value for TH_UM set value in Warm-Up at 120ï‚°C or below under LL environment 1 - 99 55
P HL_US WARMUP_120L LL Correction value for TH_US set value in Warm-Up at 120ï‚°C or below under LL environment 1 - 99 55
Q LO_WARMUP_TIME_LL Correction value for O, P applying time (timer from Ready complete) under LL environment 1 - 99 50
R HL_UM WARMUP_120H LL Correction value for TH_UM set value in Warm-Up at 120ï‚°C or above under LL environment 1 - 99 55
S HL_US WARMUP_120H LL Correction value for TH_US set value in Warm-Up at 120ï‚°C or above under LL environment 1 - 99 55
T HI_WU_TIME_LL Correction value for R, S applying time (timer from Ready complete) under LL environment 1 - 99 50
U HI_WU_FM_ON_TMP_LL Correction value for FM prior rotation start TH_UM in Warm-Up at alpha ï‚°C or above under LL
environment
1 - 99 50
V HI_WU_END_TIME_LL Correction value for Warm-Up completion time in Warm-Up at alpha ï‚°C or above under LL
environment
1 - 99 50
W HI_WU_JOB_SET_TMP_LL Correction value for Job enable TH_UM temperature (1) when Warm-Up at alpha ï‚°C or above
under LL environment
1 - 99 50
X HI_WARMUP_BORDER_LL Correction value for the threshold value alpha applying SIM43-1-U - W under LL environment 1 - 99 50
Y LO_WU_JOB_SET_TMP_LL Correction value for Job enable TH_UM temperature (1) when Warm-Up at alpha ï‚°C or below
under LL environment
1 - 99 50
Z JOBEND_FUMON_TIME LL Correction value for the after rotation time when completing a job under LL environment 1 - 99 50
AA HI_WU_JOB_SET_TMP 2 LL Correction value for Job enable TH_UM temperature (2) when Warm-Up at alpha ï‚°C or above
under LL environment
1 - 99 50
AB LO_WU_JOB_SET_TMP 2 LL Correction value for Job enable TH_UM temperature (2) when Warm-Up at alpha ï‚°C or below
under LL environment
1 - 99 50

Table of Contents

Other manuals for Sharp MX-M314N

Related product manuals