MX-M264U SIMULATION 6 – 42
Code descriptions
• Correction value: (-49 - +49), Input value: Actual input value (1 - 99)
43-22
Purpose
Function (Purpose) Used to perform the low-temperature, low-
humidity (L/L) environment correction for
the fusing temperature setting of each
paper (SIM43-04).
Section
Operation/Procedure
1) Select an item to be set with the scroll key.
2) Enter the set value with 10-key.
3) Press [OK] key. (The set value is saved.)
* PLAIN BW DUP APP CNT LL: 1 count = 1s change
Other correction values: 1 count = 1ï‚°C change
Code descriptions
• Setting value: Target value (-49 - +49), Input value: (Actual input value) 1 - 99
TH_UM Fusing thermistor main (Front surface of paper) HL_UM Heater lamp main (Heat roller for front surface of paper)
TH_US Fusing thermistor sub (Front surface of paper) HL_US Heater lamp sub (Heat roller for front surface of paper)
Correction value -49 -25 -5 0 +5 +25 +49
Input value 1 25 45 50 55 75 99
Item Display Content
Setting
range
Default
value
A HL_UM PLAIN BW DUP LL Correction value for the upper TH_UM black and white plain paper duplex under the LL
environment
1 - 99 55
B HL_US PLAIN BW DUP LL Correction value for the upper TH_US black and white plain paper duplex under the LL
environment
1 - 99 55
C PLAIN BW DUP APP CNT LL Correction value for applying number of sheets in black and white plain paper duplex under LL
environment
1 - 99 50
D HL_UM HEAVY BW DUP LL Correction value for the upper TH_UM set value of black and white heavy paper duplex under the
LL environment
1 - 99 55
E HL_US HEAVY BW DUP LL Correction value for the upper TH_US set value of black and white heavy paper duplex under the
LL environment
1 - 99 55
F HEAVY BW DUP APP CNT LL Correction value for applying number of sheets in black and white heavy paper duplex under LL
environment
1 - 99 50
TH_UM Fusing thermistor main (Front surface of paper) HL_UM Heater lamp main (Heat roller for front surface of paper)
TH_US Fusing thermistor sub (Front surface of paper) HL_US Heater lamp sub (Heat roller for front surface of paper)
Setting value -49 -25 -5 0 +5 +25 +49
Input value 1 25 45 50 55 75 99