EasyManua.ls Logo

Sharp MX-M620N

Sharp MX-M620N
412 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MX-M700N SIMULATION 7 – 55
53
53-6
Purpose
Adjustment
Function (Purpose)
Used to adjust the DSPF width detection
level.
Section
—
Operation/Procedure
1) Open the SPF paper feed guide to the maximum width posi-
tion.
2) Select MAX. POSITION with 10-key.
3) Press the [START] key.
The max. width detection level is recognized.
4) Press the [SYSTEM SETTINGS] key.
5) Open the SPF paper feed guide to the width for the A4R size.
6) Select POSITION 1 with 10-key.
7) Press the [START] key.
The A4R width detection level is recognized.
8) Press the [SYSTEM SETTINGS] key.
9) Set the manual paper feed guide to A5R size width.
10) Select POSITION 2 with 10-key.
11) Press the [START] key.
The A5R width detection level is recognized.
12) Press the [SYSTEM SETTINGS] key.
13) Open the SPF paper feed guide to the minimum width position.
14) Select MIN. POSITION with 10-key.
15) Press the [START] key.
The minimum width detection level is recognized.
If the above procedures are not completed normally, "ERROR" is
displayed. If completed normally, "COMPLETE" is displayed.
53-7
Purpose
Adjustment/Setup/Operation data output/
Check (Display/Print)
Function (Purpose)
Used to enter the SPF width detection
adjustment value.
Section
DSPF
Operation/Procedure
1) Select the number corresponding to the set item with 10-key.
2) Press the [START] key.
3) Enter the set value with 10-key.
4) Press the [START] key.
53-8
Purpose
Adjustment
Function (Purpose)
Used to adjust the document scan start
position. (Used to adjust the scanner scan
position in the SPF mode front scan.)
Section
—
Operation/Procedure
1) Enter 2 with 10-key.
2) Press the [START] key.
3) Enter the adjustment value with 10key. (1 count: 0.1mm)
4) Press the [START] key.
1
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 0-14, AND PRESS START.
0.TRAY SELECT 1 1.PRINT START
2.TRAY1 50 3.TRAY2 50 4.TRAY3 50
5.TRAY4 50 6.BPT 50 7.LCC 50
8.ADU 50 9.SPF(TOP) 50 10.SPF(HIGH) 50
11.SPF(LOW) 50 12.SPF FEED(TOP) 50
13.SPF FEED(HIGH) 50 14.SPF FEED(LOW) 50
1
SIMULATION 53-6
SPF TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1.MAX.POSITION
2.POSITION 1
3.POSITION 2
4.MIN.POSITION
Item
Setting
range
Default
1MAX.
POSITION
Max. position 0 - 1023 66
2 POSITION 1 Adjustment point 1 456
3 POSITION 2 Adjustment point 2 713
4 MIN. POSITION Min. width 791
Item
Setting
range
Default
2 MANUAL Manual adjustment
(Direct entry of a
number)
1 - 70 32
1
SIMULATION 53-7
SPF TRAY ADJUSTMENT(MANUAL). SELECT 1-4, AND PRESS
START.
1.MAX.POSITION: 66
2.POSITION 1 : 456
3.POSITION 2 : 713
4.MIN.POSITION: 791
SIMULATION 53-8
SPF SCANNING POSITION ADJUSTMENT. PRESS START.
2.MANUAL 25

Table of Contents

Related product manuals