12(108)
1.3 Technical Specifications
1.3.1 Specification
Table 1-1:Specification
Model
Max.
Temp.
Pipe
Heater
(kW)
Pump Power
(kW)
(50 / 60Hz)
Max. pump
Flow
(L / min)
(50 / 60Hz)
Pressure
(bar)
(50 / 60Hz)
Heating
Tank
Number
Main / Sub.
Oil Tank (L)
Method
Mould
Coupling*
(inch)
Inlet/Outlet
(inch)
Dimensions
(mm)
(H×W×D)
(kg)
STM-607 6 0.55 / 0.65
27 / 30 3.8 / 5 1 6 / 3.2 3/8" (2×2)
3/4 / 3/4 635x280x740
65
STM-607-D
6×2
0.55×2 /
0.65×2
27×2 / 30×2
3.8 / 5 2 6×2 / 3.2×2
3/8" (4×2)
3/4 / 3/4 655x560x740
130
STM-910 9 0.75 / 0.92
42 / 50 5.0 / 6.4
1 6 / 3.2 3/8" (2×2)
3/4 / 3/4 635x280x740
70
STM-910-D
9×2
0.75×2 /
0.95×2
42×2 / 50×2
5.0 / 6.4
2 6×2 / 3.2×2
3/8" (4×2)
3/4 / 3/4 655x560x740
140
STM-1220
12 1.5 / 1.9 74 / 84 6.2 / 7.2
1 6.8 / 11.8
3/8" (4×2)
1 / 1 795x340x845
100
STM-2440
24 2.8 / 3.4 130 / 130
8.0 / 10.2
2 11 / 16 1"(1×2)
1 / 1 900x390x935
145
STM-3650
200℃
36 4.0 / 4.0 170 / 170
8.0 / 8.0
3 14 / 16
Indirect
1
1
/
4
"(1×2)
1
1
/
4
/ 1
1
/
4
900x385x980
155
Note: 1) "D" stands for dual-heating zones. We reserve the right to change
2) Pump testing standard: Power of 50 / 60Hz, specifications without prior notice.
purified water at 20℃. ( There is ±10% tolerance
for either max. flowrate or max. pressure ).
3) "*" Stands for options.
4) Power supply: 3Φ, 230 / 400 / 460 / 575VAC, 50 / 60Hz.