1.3.2 Pump Performance
Flow rate
(L/min)
Pressure
(bar)
0
1
10 20 30 40 50 60 70 80 90 100
2
3
4
5
6
7
8
9
10
1
1
STM-1220
STM-910
STM-607
STM-3650
STM-2440
Picture 1-1Pump Performance
1.3.3 Reference Formula of Mould Controllers Model Selection
Heater Power (kW) = mould weight (kg) × mould specific heat (kcal/kg) ×
temperature difference between mould and environment () × safety coefficient
/ heating duration / 860
Note: safety coefficient can select a value from 1.3 to 1.5.
Flow Rate (L/min) = heater power (kw) × 860 / [heating medium specific
(kcal/kg) × heating medium density (kg/L)×in/outlet temperature difference
()× time (60)]
Note: Water specific heat =1kcal/kg
Heating medium oil specific heat =0.49kcal/kg
Water density =1kg/L
Heating medium oil density =0.842kg/L