89(108)
• OUTPUT MODE——heating or cooling control
• SUB HEATING——0 (only 1 group of heater)
• 5 (two or more groups of heater)
• COOLING TEMP.——35
Picture 4-7: Output Setting
9) Press MENU key to return to menu screen, then press◄/► keys to select
temp.setting, press SET key to enter setting screen, see picture below.
• H. LIMIT TEMP.——based on actual operation.
• L. LIMIT TEMP.——based on actual operation.
• TEMP. UNIT——℃ (Celsius and Fahrenheit)
• TEMP. DEGREE——0.1
• CTR TEMP BIAS——based on actual operation.
• RET TEMP BIAS——based on actual operation
• ENT TEMP BIAS——based on actual operation