For the electrical characteristic data of the two external digital inputs, see the respec‐
tive connection diagrams for the connection modules in these operating instructions.
Wiring the digital inputs of the device via a connection module:
Device Connection mod‐
ules
Digital switching
inputs
Reference
Lector621 CDB650-204 “SENS/IN 1”
“SENS/IN 2”
see "Wiring the digital inputs “Sensor
1” and “Sensor 2” of the device in
the CDB650-204", page 82
External input 1
(“EXT. IN 1”)
External input 2
(“EXT. IN 2”
see "Wiring digital inputs “External
input 1” and “External input 2” of the
device in the CDB650-204",
page 84
CDM420-0006 “Sensor 1”
“Sensor 2“
see "Wiring the digital inputs “Sensor
1” and “Sensor 2” of the device in
the CDM420-0006", page 96
External input 1
(“Aux In 1”)
External input 2
(“Aux In 2”)
see "Wiring digital inputs “External
input 1” and “External input 2” of the
device in the CDM420-0006",
page 98
Lector621 ECO CDB620-001 “Sens 1”
“Sens 2”
see "Wiring the digital inputs “Sensor
1” and “Sensor 2” of the device in
the CDB620-001", page 110
External input 1
(“In 1”)
External input 2
(“In 2”)
see "Wiring digital inputs “External
input 1” and “External input 2” of the
device in the CDB620-001",
page 112
CDM420-0001 “Sensor 1”
“Sensor 2“
see "Wiring the digital inputs “Sensor
1” and “Sensor 2” of the device in
the CDM420-0001", page 123
External input 1
(“Aux In 1”)
External input 2
(“Aux In 2”)
see "Wiring digital inputs “External
input 1” and “External input 2” of the
device in the CDM420-0001",
page 125
6.5.6 Wiring the digital outputs
Physical digital outputs on the device
The physical digital outputs “Result 1” to “Result 4” or “Result 1” and “Result 2” are
used to signal events in the read operation. Different functions can be assigned to
them independently of each other for this purpose. If the assigned event occurs, then
the corresponding digital output becomes live after the end of the read cycle for the
selected pulse duration, for example (default).
Lector621:
The full complement of digital outputs is available at each of the following locations:
Male connector of the device (M12, 17-pin, A-coded)
Open end of the adapter cable (female connector, M12, 17-pin, A-coded/open
end)
CDB650-204 connection module
The four digital outputs are available in the CDM420-0006 connection module but
reduced to two outputs (“Result1“, “Result2“). Connect the device to the
CDM420-0006 connection module using an adapter cable (female connector, M12, 17-
pin, A-coded / male connector, D-Sub-HD, 15-pin).
Lector621 ECO:
ELECTRICAL INSTALLATION 6
8022502/15NT/2020-02-11 | SICK O P E R A T I N G I N S T R U C T I O N S | Lector621