Assignment of codes to objects
A trigger (e.g. photoelectric sensor) controls the starting and stopping of the reading
process. Several objects with codes may be present in the field of view of the product
during the reading process. The product reads multiple codes simultaneously. The prod‐
uct uses the tracking function to correctly assign the codes it reads to the objects. An
object separation of at least 50mm is necessary for clear differentiation of successive
objects.
If the speed of the conveying equipment is variable, an external encoder is required for
the three-dimensional assignment of codes.