Prerequisites
•
There is a risk of burns at ambient temperatures above 32°C. If the ambient tem‐
perature is above 32°C, disassemble the optics cover and make fine adjustments
to the mounted lens within 20minutes after switching on the cooled device.
•
Lens and illumination unit are compatible with the product. You can find compati‐
ble accessories on the product page on the Internet.
•
SW2 hex key (included with delivery)
•
SW5 socket wrench, recommendation: as a torque wrench for 65Ncm
Approach
1. Switch off the supply voltage to the device.
2. Peel off the white protective sticker on the camera housing that covers the electri‐
cal connection for the illumination unit.
3. Place the camera housing on a nonslip base.
4. Remove the protective cap from the round light inlet.
5. Screw the lens unit into the C-mount thread until it engages.
6. Take 2 pairs of long screws and screw them into the tapped blind holes to mount
each spacer on the camera housing.
7. Use the 4 short screws to fasten the illumination unit to the two spacers.
8. In systems subjected to heavy vibrations, secure the screws used to mount the
lens and illumination unit using threadlocking adhesive.
9. Manually preset the sharpness and aperture of the lens unit.
10. Check the adjustment using SOPASair.
11. If the required adjustments to the lens are not carried out immediately, mount the
optics protection hood for the lens.
4.3 Assembling the product
Approach
1. Mount the product on suitably prepared mounting equipment using M5 screws
and by means of the threaded mounting holes or sliding nuts. Mounting equip‐
ment is available as an accessory.
°
Screw the screws no more than 5mm into the threaded mounting holes or
sliding nuts.
°
To do so, either use all 4 threaded mounting holes on the rear of the product
or the two sliding nuts on the side of the product.
°
Attach the optional SICK mounting equipment ordered separately using the
sliding nuts on the product.
2. In application areas with severe vibrations or shocks caused by vibrations, jolts
or abrupt changes in directions (e.g., when mounted to a manned forklift truck),
mount the product with vibration dampers. Mount the product in a freely sus‐
pended manner.
3. Align the product taking into consideration the field of view and the application
circumstances.
4. Connect the product to interfaces and supply voltage when disconnected from
voltage.
5. Start the product.
✓
The Ready status LED lights up green.
6. Perform fine tuning.
MOUNTING 4
8027859/1KN0/2023-08-02 | SICK O P E R A T I N G I N S T R U C T I O N S | Lector85x CAN I/O
21