Perceived area of field of view: H x V (mm) 1
0
Working distance in mm 5
500 x 416
1000 x 831
2000 x 1662
2500 x 2078
1500 x 1247
f = 12 mm
f = 16 mm
f = 25 mm
1D code 3
Min. resolution in mm 2
2D code 4
0.2
0.3
0.1
0.2
0.4
0.6
0.4
0.3
0.1
0.5
0.5
0.7
0.6
0.7
0.8
0.8
0.9
0.9
1.0
1.0
0 500 1000 1,500 2,000 2,500 3,000
Figure 16: Field of view diagram for V2D8505R-xxxxxxxxxx
1
Perceived field of view area: horizontal x vertical (mm)
2
Minimum resolution in mm
3
1D code
4
2D code
5
Working distance in mm
Lector85x Flex
Product type: V2D8509R-xxxxxxxxxx
10 TECHNICAL DATA
44