APPX
Appendix 5 Buffer Memory
145
A
Error code 2
The code of an error occurred in a module is stored. For error codes to be stored, refer to the following section.
Page 123 List of Error Codes
■Buffer memory address
The buffer memory address of this area is as follows.
Statuses of lower rotary switches
The current setting values of the rotary switches are stored.
■Buffer memory address
The buffer memory address of this area is as follows.
■Switch status
Statues of upper rotary switches
The current setting values of the rotary switches are stored.
■Buffer memory address
The buffer memory address of this area is as follows.
■Switch status
Buffer memory name Address
1st Module Error code 2 106
2nd Module Error code 2 146
3rd Module Error code 2 186
Buffer memory name Address
1st Module Lower Rotary Switch state 108
2nd Module Lower Rotary Switch state 148
3rd Module Lower Rotary Switch state 188
Bit Name Description
b0 Lower rotary switch settings 0 to 9
b1
b2
b3
b4 to b15 Fixed to 0
Buffer memory name Address
1st Module Upper Rotary Switch state 109
2nd Module Upper Rotary Switch state 149
3rd Module Upper Rotary Switch state 189
Bit Name Description
b0 Upper rotary switch settings 0 to 9
b1
b2
b3
b4 to b15 Fixed to 0