5 Mounting
5.1 Mounting requirements
■
C
om
ply with technical data such as the permitted ambient conditions for operation
of the sensor (e.g., temperature range, EM interference), see "technical data",
page 41.
■
Protect the sensor from direct sunlight.
■
Only mount sensor with the intended accessories.
Mounting location
When se
lecting the mounting location, the following factors must be considered:
■
The mounting location must be as free from (electro)magnetic disturbance fields
as possible
5.2 Optional accessories
Table 5: Optional accessories
Part number Designation
4107585 Control panel mounting
4106971 T-slot adapter
5.3 Mounting
Insert sensor into the slot from above. The PW
R LED
2)
lights up green .
1
Insert sensor
2
Turn sensor
3
Tighten screws (tightening torque max. 0.1 Nm)
2)
PW
R LED = Power LED
MOUNTING 5
8025942/2020-07-16 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-G with 2 / 3 switching points and IO-Link (up to 16 switching points)
19
Subject to change without notice