Loading...
ON
Qint SP
OFF OFF
OFF
OFF
ON
ON
ON
OFF
1 2 1
3
Figure 6: Switching behavior after Manual Teac
h
1
Hysteresis
2
Width of the switching point
3
Position
There is no Dynamic P
ilot during manual teach-in of the switching points. The switching
point width is 2 mm according to the factory setting and can be adjusted via the Teach
menu (1 – 5 mm).
3.3.5 Switching behavior after Dynamic Teach of 2 switching points
If the sensor, during Dynamic Teach, detects teach 2 x piston status v = 0, 2 switching
point
s ar
e set.
NOTE
Dynamic
Teach and Dynamic Pilot only start working from a speed of v > 25 mm/s.
Example: Arrangement of switching points for dynamic teach-in of 2 switching points
on a pneumat
ic cylinder
The 2 switching points are always arranged as follows during dynamic teach-in: Qint1
lies in the direction of the cable outlet and Qint2 in the direction of the sensor fixing
screw. It does not matter which position is approached first.
Table 2: Switching behavior with 2 switching points
1.) Output position v= 0.
No s
witching point is
defined at the output posi‐
tion of the magnet.
v = 0