3. Connect "Power/Serial Data/CAN/I/0" connection (male connector, M12, 17-pin,
A-coded) to the corresponding female connector on the connection module using
the suitable cable 7.
4. If necessary, connect a read cycle trigger sensor, such as a photoelectric retro-
reflective sensor, to the “Sens/IN 1” (CDB650-204) or “Sensor 1”
(CDM420-0006) digital switching input of the connection module. For
CDB650-204: see "Wiring digital switching inputs “Sensor 1” and “Sensor 2” of
the device in the CDB650-204", page 109. For CDM420-0006 see "Wiring digital
switching inputs “Sensor 1” and “Sensor 2” of the device in the CDM420-0006",
page 122.
5. Supply the device with the required voltage depending on the length of the con‐
necting cable 7.see "Supply voltage", page 63 .
After successful initialization, the “Device Ready” LED lights up green.
6. Turn on the PC and start Windows.
RFU63x-041xx (without internal antenna)
SOPAS ETSOPAS ET
...
...
1
2
V
S
GND
PC
"Ethernet" (Aux 2)
...
1 4
RFU63x-
041xx
"Power/Serial Data/CAN/I/O"
(Aux 1, Host 1)
External antennas 4
5
Cable 6Cable 7
Cable 8
2
11 10 12
Trigger
sensor
SGND
Sens 1
V
S
1
Out
GND
V
S
3
Connection
module
EthernetEthernet
Configuration
Reading result
display
Transponder
access
Reading
diagnostics
Figure 31: Commissioning: Electrical connection block diagram of the RFU630-041 xx with
optional connection module
1
Reading pulse trigger
2
Supply voltage V
S
3
CDB650-204 or CDM420-0006 connection module
4
External antennas (minimum number 1), e.g. RFA630-000 for Europe/Saudi Arabia/
South Africa region
5
Configuration or diagnostics
6
Adapter cable (male connector, M12, 4-pin, D-coded / male connector, RJ-45, 8-pin)
7
For CDB650-204: Connection cable 1:1 (female connector, M12, 17-pin, A-coded / male
connector, M12, 17-pin, A-coded)
For CDM420-0006: Adapter cable (female connector, M12, 17-pin, A-coded / male con‐
nector, D-Sub-HD, 15-pin)
8
Cable (female connector TNC / female connector, TNC)
1
Trigger sensor for read cycle
2
Supply voltage V
S
(V
S
= U
V
)
3
Connection module CDB650-204 or CDM420-0006
4
External antennas (optional), e.g. RFA630-000
10)
5
Configuration with SOPAS ET, prepared representation of the read result, transponder
access or reading diagnostics
6
Adapter cable (male connector, M12, 4-pin, D-coded/male connector, RJ-45, 8-pin)
10)
For regional assignment, see online data sheet at: www.sick.com/RFU63x
6 ELECTRICAL INSTALLATION
56
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x 8014335/ZTL9/2018-10-14 | SICK