For CDB650-204: Connection cable 1:1 (female connector, M12, 17-pin, A-coded/male
connector, M12, 17-pin, A-coded)
For CDM420-0006: Adapter cable (female connector, M12, 17-pin, A-coded / male con‐
nector, D-Sub-HD, 15-pin)
8
Cable (male connector, TNC reverse/male connector, TNC reverse)
Procedure:
1. Connect the communication interface (e.g., Ethernet) of the device directly to the
PC using the suitable cable 6.
2. Connect external antennas (maximum 4, e.g. RFA630-000) to the antenna inputs
of the device by means of suitable connecting cables 8. At least one external
antenna is required!
3. Connect "Power/Serial Data/CAN/I/0" connection (male connector, M12, 17-pin,
A-coded) to the corresponding female connector on the connection module using
the suitable cable 7.
4. If necessary, connect a read cycle trigger sensor, such as a photoelectric retro-
reflective sensor, to the “Sens/IN 1” (CDB650-204) or “Sensor 1”
(CDM420-0006) digital switching input of the connection module. For
CDB650-204: see "Wiring digital switching inputs “Sensor 1” and “Sensor 2” of
the device in the CDB650-204", page 109. For CDM420-0006 see "Wiring digital
switching inputs “Sensor 1” and “Sensor 2” of the device in the CDM420-0006",
page 122.
5. Supply the device with required voltage depending on the length of the connecting
cable 7. see "Supply voltage", page 63.
After successful initialization, the “Device Ready” LED lights up green.
6. Turn on the PC and start Windows.
RFU65x-101xx
Cable 6 Cable 5
SOPASSOPAS
"Power/Serial Data/CAN/I/O"
(Aux 1, Host 1)
...
...
1
2
V
S
GND
PC
"Ethernet" (Aux 2)
Ready
Result
RF
Data
CAN
LNK TX
microSD
TeachIn
Antenna
Sync
Userdef.
Read Diagn
RFU65x-101xx
2
11 10 12
Trigger
sensor
SGND
Sens 1
V
S
1
Out
GND
V
S
3
Connection
module
4
EthernetEthernet
Configuration
Reading result
display
Transponder
access
Reading
diagnostics
Figure 32: Commissioning: Electrical connection block diagram of the RFU65x-101xx with
optional connection module
1
Reading pulse trigger
2
Supply voltage V
S
3
CDB650-204 or CDM420-0006 connection module
4
Configuration, diagnosis, transponder access or display of read results
5
Adapter cable (male connector, M12, 4-pin, D-coded / male connector, RJ-45, 8-pin)
6
For CDB650-204: Connection cable 1:1 (female connector, M12, 17-pin, A-coded / male
connector, M12, 17-pin, A-coded)
For CDM420-0006: Adapter cable (female connector, M12, 17-pin, A-coded / male con‐
nector, D-Sub-HD, 15-pin)
ELECTRICAL INSTALLATION 6
8014335/ZTL9/2018-10-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
57
Subject to change without notice

Table of Contents

Other manuals for SICK RFU62 Series

Related product manuals