4. Programming (Teach In)
Requirement:
Figure 7: Requirements for Teach-In
Encoder okay.
Power supply U
1
(Pin 25/45) connected.
In case of difference see error messages.
4.1 Set programming
Figure 8: Teach-In activation
Connect wire bridge at pin 13/14.
In programming mode the signal conversion is out of function.
4.2 Teach in "min" position
Figure 9: Teach-In "min" - position
• Set the mechanics into "min" position.
• Push the teach in-button S8 until the LED is on continuous.
• "min" position is stored. Analogue output will be 0 V (0/4 mA).
Position
"min"
stored
on
flash
8026616/2021-03-11 • Subject to change without notice • SICK AG • Waldkirch • Germany • www.sick.com