3 Product description
3.1 Scope of delivery
Scope of delivery
No. of
units
Component Note
1 Device in the version ordered -
1 Terminal bracket -
1 Printed safety notes, multilingual Brief information and general safety notes
Further topics
•
Accessories
The actual scope of delivery may differ for special designs, additional orders or due to
the latest technical changes.
3.2 Type code
Type code structure
UC40 – a b c d e f
Position Description Characteristic
a Generation 1: 1. Generation
b Principle of operation 1: Button operation
c Operating range 2: 65 mm ... 350 mm
3: 200 mm ... 1,300 mm
4: 350 mm ... 3,400 mm
d Connection technology 1: male connector, M12, 5-pin
e Housingmaterial 1: PA66 plastic
f Output function B: 1 output
•
1 push-pull digital output with IO-Link 1.1
H: 2 outputs
•
1 push-pull digital output with IO-Link 1.1
•
1 analog output (current and voltage) or push-pull
digital output with IO-Link 1.1 (selectable)
3 PRODUCT DESCRIPTION
10
O P E R A T I N G I N S T R U C T I O N S | UC40 8027772//2022-08-11 | SICK
Subject to change without notice