WLL190T-2 Photoelectric switches for fibre-optic cables
2007-08-24 SENSICK 1 9
dIG: Numeric display (factory setting),
bAr: bar display,
Pct: Percentage display,
oFF: display inactive in RUN mode.
* Only for activated counting function (3.4 cnt):
cnt: counting display,
tcnt: display total count.
3.2 Display settings
1. Selector switch to RUN
2. Operating mode Configuring
active
3. In the basic menu, select
Expert mode by pressing the
arrow keys.
4. Expert mode is shown on the
display
 

6. In Expert mode, select display
settings by pressing the arrow
keys
5. Press Mode key
7. Display settings are shown
9. Select between numeric
display (dIg), bar display (bAr),
percentage display (Pct),
normal counting display (cnt),
total count display (tcnt) and
inactive display using arrow
keys
10. Finish selection with Mode key
11. Close Expert mode with arrow
key
8. Press Mode key
12. Finish selection with Mode key
5. Press Mode key
13. Expert mode is shown on the
display
14. Select ending the adjustment
(Exit)
15. Finish selection with Mode key
*
*
WLL190T-2 Photoelectric switches for fibre-optic cables
20 SENS ICK
2007-08-24
1. Selector switch to RUN
2. Operating mode Configuring
active
4. In the basic menu, select
Expert mode by pressing the
arrow keys
5. Expert mode is shown on the
display
6. Press Mode key
7. In Expert mode, select
detection mode by pressing
the arrow keys
8. Detection mode is shown on
the display
11. Finish selection with Mode key
 





The switching output is only activated dependent on the slope of
the positive/negative edge of the signal path, with either the rising
or the trailing edges being relevant.
Stnd: Standard mode (factory setting),
hd
_
l_: Dynamic switching threshold  trailing edge,
hd_l
_
: Dynamic switching threshold  rising edge,
diFF: Differential detection (only available in bus mode).
10. Select between normal detec-
tion (Stnd), detection  trailing
edge (hd
_
l_), detection  ris-
ing edge (hd_l
_
) and differen-
tial detection (dIFF) by press-
ing the arrow keys
3.3 Detection mode
12. Close Expert mode with arrow
key
3. Press Mode key
9. Press Mode key
13. Finish selection with Mode key
Typical applications: undefined, changing scanning distances of
the objects.
14. Expert mode is shown on the
display
15. Select ending the adjustment
(Exit)
16. Finish selection with Mode key

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK WLL190T-2 and is the answer not in the manual?

SICK WLL190T-2 Specifications

General IconGeneral
BrandSICK
ModelWLL190T-2
CategorySwitch
LanguageEnglish

Related product manuals