6.3 Technical Data
In order to comply with the EMC Directive 2014/30/EU the device must be
operated with an external line filter. You find a list of the line filters available
at SIEB & MEYERin the appendix (see page 110).
Device variant
EF IF EC IC
Rated phase current of the output stage
(±3 %)
20 A
p
/ 14 A
rms
28 A
p
/ 20 A
rms
Peak phase current of output stage
(±3 %)
40 A
p
/ 28 A
rms
80 A
p
/ 56 A
rms
40 A
p
/ 28 A
rms
80 A
p
/ 56 A
rms
Max. time for peak current 0,4 s 0,4 s
Max. temperature in IGBT module 85° C 85° C
Max. output frequency 4000 Hz 4000 Hz
Output frequency stability ≤ 0.2 % ≤ 0.2 %
Mains supply (1-phase) - 115 V
AC
-10 % to 230 V
AC
+10 %
50 Hz / 60 Hz
Mains supply (3-phase) 200 V
AC
-10 % to 480 V
AC
+10 %
50 Hz / 60 Hz
230 V
AC
±10 %
50 Hz / 60 Hz
DC link voltage 280 V
DC
-10 % to 675 V
DC
+10 % 160 V
DC
-10 % to 325 V
DC
+10 %
Capacity of DC link 560 µF 2240 µF
Output power S1 (1-phase) - 3.5 kVA at 20 A
rms
/ 200 V
AC
Output power S1 (3-phase) 9.7 kVA at 14 A
rms
/ 400 V
AC
6.9 kVA at 20 A
rms
/ 200 V
AC
Short circuit current rating (SCCR) 5 kA 5 kA
Power loss in rated operation 380 W To be defined
Max. mains phase current 12.7 A
rms
18 A (3-phase 230 V
AC
)
Logic supply
(1)
18 – 28 V
DC
(0.5 A) 18 to 28 V
DC
(0.5 A)
Power loss logic unit 12 W 12 W
Power loss of power unit Max. 5 % of the output motor power
Min. external ballast resistor 22 Ω 10 Ω
Internal ballast resistor
(2)
39 Ω / 50 W
With internal ballast resistor the rated
current must be reduced by
0.26 % per 1 W ballast power.
22 Ω / 50 W
With internal ballast resistor the rated
current must be reduced by
0.26 % per 1 W ballast power.
Ballast threshold
800 V
DC
380 V
DC
Overvoltage threshold 850 V
DC
410 V
DC
Undervoltage threshold 40 V
DC
40 V
DC
Ambient temperature range 5 °C to 60 °C at a maximum relative humidity of 85 % (without moisture condensa‐
tion)
100 % rated current up to max. 40 °C. At higher temperatures the rated current
must be reduced by 1.5 % per 1 °C.
Max. site altitude
2000 m above MSL
Above 1000 m above MSL the power must be reduced by 1.5 % per 100 m.
W
Device Description
Drive System SD2S - Hardware Description 0362X49xy / 0362129xy 33
6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SIEB & MEYER SD2S 0362249xy and is the answer not in the manual?

SIEB & MEYER SD2S 0362249xy Specifications

General IconGeneral
BrandSIEB & MEYER
ModelSD2S 0362249xy
CategoryDC Drives
LanguageEnglish

Related product manuals