Safety Instructions
Protect the device against mechanical damage! Ensure that single shock loads do
not exceed 40 m/s
2
.
Protect the device against dirt and humidity.
Make sure that dust plugs are plugged on optical fiber connectors equipped
with them during transport of the device. Otherwise, recommissioning is poten-
tially not possible.
Never touch electronic components.
The following climatic conditions apply to the storage. If required, appropriate measures
must be taken to ensure these climatic conditions (installation of heating/air conditioning
systems etc.):
The storage area must be clean (dust-free, if possible), dry and well-ventilated.
No storage in the open.
The storage temperature must be in the range of −25 °C to +55 °C (−13 °F to
+131 °F). Shortly it may be +70 °C (+158 °F).
The relative humidity on the storage premises must be in the range of 5 % to 75 %
(no bedewing).
Sudden changes of the temperature or the humidity should be prevented.
Avoid stacking of the devices during transport and storage.
The maximum storage period is 2 years. Electrolytic capacitors produce high leakage
currents when a voltage is applied after a long storage period without applied voltage
and must be reformed. For this, the operating voltage is applied via a 1 series resistor
for one hour. Please contact the SIEB & MEYER service department for details.
3.6 Installation
NOTICE
Damage of electrostatically sensitive components due to improper handling
Never touch electronic components..
Note
Consider specific mounting instructions for your device.
Mechanical installation conditions for the system according to DIN EN 61800-2:
„Vibrations must remain within the limit values of the IEC 60721-3-3,
class 3M1,standard for fixed equipment.“
Tab. 1: Vibration limits of the system
Frequency [Hz] Amplitude [mm] Acceleration [m/s²]
2 ≤ f < 9 0.3 Not applicable
9 ≤ f < 200 Not applicable 1
Tab. 1: Vibration limits of the system
"Vibrations which exceed these limits, or the use on mobile equipment, are considered
as abnormal mechanical conditions."
Operating conditions:
The following requirements are to be considered for the installation and the operation of
the device. Noncompliance with theses requirements is regarded as abnormal operat-
ing condition:
14 Drive System SD2 - Hardware Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SIEB & MEYER SD2S and is the answer not in the manual?

SIEB & MEYER SD2S Specifications

General IconGeneral
BrandSIEB & MEYER
ModelSD2S
CategoryControl Unit
LanguageEnglish

Related product manuals